Electrical safety barriers

select brand


Val.co srl

Safety barrier - SAFE -SW

The Safe-SW is an on or off safety barrier manufactured by Valco. Operating...

Safety barrier - SAFE -SW

The Safe-SW is an on or off safety barrier manufactured by Valco. Operating at a power supply of 20VDC to 35VDC, it features an insulation ranging between 250VCA to 250 VDC. In addition, it has a DIN mounting rail measuring 35mm and an ATEX II 1G EEx-ia IIC T4-T5-T6 certification from BASEEFA.

Safety barrier - SAFE - POT

The Valco safety barriers function to repeat the NO or NC signal contact that comes from Multipoint I level switches...

Safety barrier - SAFE - POT

The Valco safety barriers function to repeat the NO or NC signal contact that comes from Multipoint I level switches positioned in hazardous areas.They allow galvanic insulation between the areas under control.They have BASEEFA approval of 01.ATEX.7141 II 1G EEx iaIIC T6.

These safety barriers have LED indicator and operates in one or two channels from hazardous areas.They have IP40 protection while dimensions are 120x120x15mm
IDEC USA

Intrinsically safe safety barrier - EB3C series

Intrinsically Safe Relay Barriers are essential components of intrinsically safe applications. These devices limit current, voltage, & total...

Intrinsically safe safety barrier - EB3C series

Intrinsically Safe Relay Barriers are essential components of intrinsically safe applications. These devices limit current, voltage, & total energy delivered to a sensor or any other actuator instrument located in a hazardous area. When used in areas with hazardous chemicals, gases or other ignitable atmospheres, limiting the energy is required to prevent any possible fires & explosions from occurring. Dry contact switches can be connected to the EB3C. Illuminated switches also can be connected with the combination of the EB3S Relay and the EB3L Lamp Barriers.

Intrinsically safe safety barrier - EB3L series

Intrinsic Safety Lamp Barriers are essential components of an intrinsically safe application....

Intrinsically safe safety barrier - EB3L series

Intrinsic Safety Lamp Barriers are essential components of an intrinsically safe application. These devices are to limit the voltage and current to prevent ignition in hazardous areas. 126 different types of pilot lights and buzzers can be connected. Illuminated push buttons and selector switches also can be used with the combination of EB3L lamp and EB3C relay barriers.
IDEC

Intrinsically safe safety barrier - EB3C

The EB3C series provides a cost effective Intrinsic Safety Barriers alternative. Available in 100-240VAC or 24VDC and with from 1 to 16 channels, EB3C series has many options to meet your...

Intrinsically safe safety barrier - EB3C

The EB3C series provides a cost effective Intrinsic Safety Barriers alternative. Available in 100-240VAC or 24VDC and with from 1 to 16 channels, EB3C series has many options to meet your...
{{item.name}}