Liquid analyzers: disinfection (chlorine, ozone...)

select brand


Hanna Instruments

Total Cl analyzer / Cl - 0 - 5 mg/l | PCA 310 series

Implements the DPD colorimetric method to determine chlorine concentration
One point calibration of photometric cell
Control time cycles adjustable between 3 to 90 minutes
Proportional control of chlorine concentration
Out of range measurement and self-diagnostic system alarms
Parameter control through analog output or dedicated relays
Logging space...

Total Cl analyzer / Cl - 0 - 5 mg/l | PCA 310 series

Implements the DPD colorimetric method to determine chlorine concentration
One point calibration of photometric cell
Control time cycles adjustable between 3 to 90 minutes
Proportional control of chlorine concentration
Out of range measurement and self-diagnostic system alarms
Parameter control through analog output or dedicated relays
Logging space of up to of 3500 measurements and alarm status
Multi-language support
RS485 connectivity


Models

The HANNA PCA 300 series models are chlorine, bromine or iodine and pH, ORP and temperature process analyzers which continuously monitor a sample stream and control the dosing to adjust the chlorine, bromine or iodine content and pH.

From drinking and wastewater treatment to the pool and spa sanitation, the monitoring of chlorine, bromine or iodine levels has an important bearing on public health as well as ROI and efficiency for heating system and industrial applications.

The PCA 3X0 series monitors the free chlorine or total chlorine in the 0 to 5.0 mg/L range;

In the DPD Colorimetric method, N, N-Diethyl-p-phenylene-Diamine indicator and a buffer are mixed with the sample. Free available chlorine oxidizes the DPD indicator reagent at a pH between 6.3 and 6.6 to form a magenta colored compound. The intensity of the resulting color is proportional to the concentration of chlorine in the sample. The purpose of the buffer solution is to maintain the proper pH.
Dr. A. Kuntze

Chlorine (Cl) and ozone (O3) measuring unit - max. 30 mg/l | Krypton K



Low maintenance by patented Automatic Sensor Cleaning ASR®
Pressure-proof up to 6 bar
Higher safety by integrated flow...

Chlorine (Cl) and ozone (O3) measuring unit - max. 30 mg/l | Krypton K



Low maintenance by patented Automatic Sensor Cleaning ASR®
Pressure-proof up to 6 bar
Higher safety by integrated flow...

Cl analyzer / free Cl - max. 20 mg/l | K 100 (W) DES

Description
The instruments of the K100 series are high-quality single-channel measuring and control instruments to measure disinfectants, pH/ORP, conductivity or gas. Each instrument has one measuring input and a temperature input....

Cl analyzer / free Cl - max. 20 mg/l | K 100 (W) DES

Description
The instruments of the K100 series are high-quality single-channel measuring and control instruments to measure disinfectants, pH/ORP, conductivity or gas. Each instrument has one measuring input and a temperature input. You can select automatic or manual temperature compensation.
All instruments contain a PI controller with two set points. Data can be read out via 0/4-20mA output or optionally via serial interface.
The K100 provides various safety features: A freely adjustable start delay prevents wrong dosing after power failure, and the controller is shut off automatically in a low-water situation. You can activate dosage check, a function that stops the controller and issues an alarm if prolonged dosing with 100% does not result in reaching the set point or the p range, possibly due to damaged feed lines. Two limits can be defined, to issue an alarm if the measurement exceeds the limits.

Chlorine analyzer / portable - 0.01 - 11 mg/l | Radon FM

The Radon photometer can be used in practically every area of water analysis. It requires absolutely...

Chlorine analyzer / portable - 0.01 - 11 mg/l | Radon FM

The Radon photometer can be used in practically every area of water analysis. It requires absolutely no maintenance in because of the high-precision optics with its high-quality interference filters and long-term stable for its LEDs light-source. Accurate and consistent results are obtained quickly. The instrument uses well proven tablet reagents with a long shelf-life.
{{item.name}}