Liquid analyzers: disinfection (chlorine, ozone...)

select brand


Mitsubishi Chemical Analytech

Chlorine analyzer / sulfur - TOX-100

This Analyzer from Apache is a horizontal furnace combustion...

Chlorine analyzer / sulfur - TOX-100

This Analyzer from Apache is a horizontal furnace combustion type. It is used to measure TOX, AOX, EOX, POX, TX, TS and TN parameters. In addition, the tool processes concentrations from ppb to low percent levels.

Chlorine analyzer / sulfur - NSX-2100H

This is one of the latest elemental analyzers, being part of the NSX-2100H series. The item is a new horizontal furnace system, which comes with coulometric detector. The Chlorine...

Chlorine analyzer / sulfur - NSX-2100H

This is one of the latest elemental analyzers, being part of the NSX-2100H series. The item is a new horizontal furnace system, which comes with coulometric detector. The Chlorine analyzer is a cost effective solution and comes with superior cell stability, allowing ppb level titration analysis, with the same detector being used for Sulfur as well.

The NSX-2100H comes with a modular system configuration, along with various options of sample injectors and other detectors. The manufacturer also makes available Chemiluminescence Nitrogen and UVFL sulfur. Note that the system provides improved and fast performance, providing optimum plant operation and being suitable for catalyst control.

Total Cl analyzer / Cl - ISO9562, EPA9020 | AOX-200

The AOX-200 from Mitsubishi Chemical Analytech, is a total chlorine (Cl) analyzer used for drinking water, surface water and...

Total Cl analyzer / Cl - ISO9562, EPA9020 | AOX-200

The AOX-200 from Mitsubishi Chemical Analytech, is a total chlorine (Cl) analyzer used for drinking water, surface water and sludge in AOX application. With its open top vertical tube, it saves maintenance cost of the combustion tube, as well as provide an ease of operation.

Its small compact design also saves space in the laboratory, and makes it easy to move, and check mechanical and electrical components. The AOX-200 prevents gas leakage and sulfuric acid flush back.
Swan AG

Chlorine (Cl) and ozone (O3) measuring unit - 0 - 5 mg/l | AMI Trides

Swan's Monitor AMI Trides Microprocessor-Controlled Systems are generally used for automatic and constant measurement...

Chlorine (Cl) and ozone (O3) measuring unit - 0 - 5 mg/l | AMI Trides

Swan's Monitor AMI Trides Microprocessor-Controlled Systems are generally used for automatic and constant measurement of disinfectants in potable water and swimming pool applications. The range of disinfectants include hypchlorous acide, ozone bromine, iodine, and more. These systems contain zero indicators and consumable elements, and feature optional pH measurement for pH on-line compensation whenever measuring free chlorine levels.

Chlorine (Cl) and ozone (O3) measuring unit - 0 - 6 ppm | AMI Codes-II

This colorimetric process analyzer is used for measurement and dosing control of disinfectants, including hypochlorus, chlorine dioxide, ozone, iodine, bromine and monochloramine. In addition to this, the continuous online determination of disinfectants is based on the DPD calorimetric...

Chlorine (Cl) and ozone (O3) measuring unit - 0 - 6 ppm | AMI Codes-II

This colorimetric process analyzer is used for measurement and dosing control of disinfectants, including hypochlorus, chlorine dioxide, ozone, iodine, bromine and monochloramine. In addition to this, the continuous online determination of disinfectants is based on the DPD calorimetric methods, while the item is also applicable for water containing additives, including cyanuric acids, antiscalants and corrosion inhibitors.

The complete system includes measurement and control electronics, as well as flow indicators, photometer, reaction chambers and reagent dosing systems and containers. In addition to this, the pH measurement with temperature compensation is available as option, while the usual dosing services are suitable for disinfectants and pH control, being connected through relays or analog output signals. There are two independent controllers that you can operate simultaneously, while the temperature sensor, cables and electronics board are all included. The third signal output is selectable as current signal output, and the interface RS485 is also worth mentioning.

Cl analyzer / total Cl - AMI Codes-II TC

Swan's Analyzer AMI Codes-II TC is a colorimetric process analyzer used for the measurement and dosing control of total chlorine and calculation of dichloramine....

Cl analyzer / total Cl - AMI Codes-II TC

Swan's Analyzer AMI Codes-II TC is a colorimetric process analyzer used for the measurement and dosing control of total chlorine and calculation of dichloramine. The instrument's measurement time tc1 is at 3-5 seconds, while the measurement time tc2 is at 2 minutes. Measurement values include total chlorine 1, total chlorine 2, dichloramine, flow, as well as pH and temperature, if an extension is installed.

The analyzer is a complete system which includes measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.

Chlorine analyzer / in-line - 0 - 5 ppm | AMI Codes-II CC

The AMI Codes-II CC model is manufactured by Swan Analytical Instruments, and is a colorimetric process analyzer that is utilized for measurement and dosing control...

Chlorine analyzer / in-line - 0 - 5 ppm | AMI Codes-II CC

The AMI Codes-II CC model is manufactured by Swan Analytical Instruments, and is a colorimetric process analyzer that is utilized for measurement and dosing control...
CHEMITEC

Temperature analyzer / residual chlorine / chlorine dioxide / free - 4293 series

Chemitec's 4293 series is a line of chlorine, chlorine dioxide or ozone analyzers. The system was developed to measure temperature with the use of an additional PT100 probe.

The...

Temperature analyzer / residual chlorine / chlorine dioxide / free - 4293 series

Chemitec's 4293 series is a line of chlorine, chlorine dioxide or ozone analyzers. The system was developed to measure temperature with the use of an additional PT100 probe.

The series features as "CAL" function key, used for directly accessing the calibration menu, as well as a "GRAPH" function key, which is used to access the measure graphs. It has an LCD graphic array, with dimensions of 128x64 and background illumination.

It is provided with an internal data logger of flash 4 Mbit, with the possibility of graphic and table visualization of trends of measurements. The system is also equipped with a serial interface RS485 MOD BUS RTU.

Residual chlorine analyzer / temperature / chlorine dioxide / hydrogen peroxide - 3593 series

Measurement of Free Residual Chlorine / Chlorine Dioxide / Ozone / Peracetic acid /
Hydrogen peroxide
Measuring of Temperature using the PT100/PT1000 or NTC (Optional) probe
Automatic Compensation of Temperature
Programming key pad with 4 keys
"CAL" Function Key to direct access to the calibration menu
"GRAPH" Function Key to direct access to the graphs of...

Residual chlorine analyzer / temperature / chlorine dioxide / hydrogen peroxide - 3593 series

Measurement of Free Residual Chlorine / Chlorine Dioxide / Ozone / Peracetic acid /
Hydrogen peroxide
Measuring of Temperature using the PT100/PT1000 or NTC (Optional) probe
Automatic Compensation of Temperature
Programming key pad with 4 keys
"CAL" Function Key to direct access to the calibration menu
"GRAPH" Function Key to direct access to the graphs of measure
LCD Graphic display 128x64 with background illumination
Internal Data Logger (flash 4 Mbit) with the possibility of graphic and table visualisation of
measurement trends
1 RS485 Serial outlet
1 Programmable Analogical Outlet
2 Relay Outlets for intervention thresholds
1 Relay Outlet for Instrument Anomaly Alarm or Temperature Set Point
1 Relay Outlet for Probe Washing or Temperature Set Point
1 Digital Entrance for disabling of doses
Main hardware characteristics of the electronic device
The hardware structure of this periphery is based on the adoption of extremely new CPU
CMOS with 16 bits developed specifically for the execution of the so-called embedded
applications.
The card uses an EEPROM to store the Set-up data and flash memories for storage of the
archives of historical data and LOG files of events.
The Card has 1 RS485 gate (opto-isolated) for local networks used for connections with local
communication devices (configuration computer, terminals and remote controls etc).
The card integrates a Real Time Clock (clock with date) that allows the software to storage
figures in a chronological order.

Free Cl analyzer / Cl - ACP 4001-2/CL2 series

The ACP 401-2/CL2 series, manufactured by Chemitec, is a multiparameter power unit for the...

Free Cl analyzer / Cl - ACP 4001-2/CL2 series

The ACP 401-2/CL2 series, manufactured by Chemitec, is a multiparameter power unit for the determination of free chlorine with photometric method and temperature. It has an accuracy of 1% f.s. and a resolution of 0.01ppm. Furthermore, this device has an LCD STN 240x128 backlighted display and can be programmed through its keyboard with 4 bubble keys.

Cl analyzer / free Cl - ACP 4001-2/CL2 Tot series

This metering unit that is supplied by Chemitec is a multi-powered unit that is...

Cl analyzer / free Cl - ACP 4001-2/CL2 Tot series

This metering unit that is supplied by Chemitec is a multi-powered unit that is ideally used in dealing with applications that are concerned with the measurement of total chrorine and temperature levels. This product is engineered to provide these services through the use of the photo metric method of measurement.
{{item.name}}