Liquid analyzers: disinfection (chlorine, ozone...)

select brand


WTW

Chlorine analyzer / in-line - Chlorine 3000

The Chlorine 3000 is an analyzer manufactured by WTW. It operates photometrically using...

Chlorine analyzer / in-line - Chlorine 3000

The Chlorine 3000 is an analyzer manufactured by WTW. It operates photometrically using the DPD method, in compliance to US EPA.

The analyzer ensures low consumption reagents in a dry state. It needs to be filled with water within 30 days to operate. The unit measures from 0 mg/l to 10 mg/l, with a resolution of 0.01 mg/l.
Extech

Chlorine analyzer / portable - EX800

EX800: ExStik® 3-in-1 Chlorine, pH, Temperature Kit
Chlorine, pH and Temperature measurements with all the necessary accessories

Features:

Includes CL200 meter, pH electrode, reagent tablets, 4 plastic...

Chlorine analyzer / portable - EX800

EX800: ExStik® 3-in-1 Chlorine, pH, Temperature Kit
Chlorine, pH and Temperature measurements with all the necessary accessories

Features:

Includes CL200 meter, pH electrode, reagent tablets, 4 plastic...
Hach

Chlorine analyzer / in-line - CL17

* 0 to 5 mg/L range, dual, fully-adjustable set-point alarms
* IP62 enclosure rating,...

Chlorine analyzer / in-line - CL17

* 0 to 5 mg/L range, dual, fully-adjustable set-point alarms
* IP62 enclosure rating, suitable for indoor installation
* Automatic, self-testing diagnostics
* Minimal routine maintenance required
* Colorimetric DPD chemistry - fast, reliable, economical
* Unattended operation up to 30 days
* Manual or automatic feed pump control

Chlorine analyzer / in-line - CLF10

The CLF10 sc analyzer uses Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH...

Chlorine analyzer / in-line - CLF10

The CLF10 sc analyzer uses Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow. Free chlorine measurement with an amperometric analyzer, such as the CLF10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management. The CLF10sc free chlorine analyzer allows for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed. Product includes free chlorine sensor, chlorine sensor block, sc200 controller, scGateway, stainless steel panel, pH flow cell and pHd sensor.

Residual chlorine analyzer / Cl / in-line - 9184sc

The low minimum detection limit and wide measurement range of the Hach 9184 sc Amperometric Free Chlorine Sensor makes it ideal...

Residual chlorine analyzer / Cl / in-line - 9184sc

The low minimum detection limit and wide measurement range of the Hach 9184 sc Amperometric Free Chlorine Sensor makes it ideal for efficient residual chlorine monitoring. Continuously measures hypochlorous acid (HOCl), temperature, and pH.

* Low Minimum Detection Limit for Efficient Residual Chlorine Monitoring
* Acidification Unit
* Wide Measurement Range
* Continuous Chlorine Measurement
* Compatible with Hach's Plug and Play Digital Controllers
{{item.name}}