I/O modules

select brand


Aventics GmbH

Fieldbus I O module - AS-i

Field bus module with IP 65 protection and AS-i compatible runs on 24VDC with 0.03A...

Fieldbus I O module - AS-i

Field bus module with IP 65 protection and AS-i compatible runs on 24VDC with 0.03A...

Fieldbus I O module - BDC

This bus module with driver features a B-design and die-cast aluminum housing. Ambient temperature ranges from 0 to 50 degrees Celsius. The operational voltage...

Fieldbus I O module - BDC

This bus module with driver features a B-design and die-cast aluminum housing. Ambient temperature ranges from 0 to 50 degrees Celsius. The operational voltage (electronics) is 24V DC. For actuators, total current is 3A.

The maximum number of solenoid coils is 32. The protection class (with plug) is IP65. Additional features include a socket port valve system, 3A total current for actuators, 2.0mm strip, maximum power consumption per coil of 0.1A and an electronics voltage tolerance of -15 to +20%. Generic immunity standard is IEC 61000-6-2 (in accordance with norm) and emission standard is EN 61000-6-4.

Fieldbus I O module - CMS

The product housing is a die-cast aluminum optional field bus connection with ambient min. temp. of + 0°C and max. temp. of + 50°C. The protection...

Fieldbus I O module - CMS

The product housing is a die-cast aluminum optional field bus connection with ambient min. temp. of + 0°C and max. temp. of + 50°C. The protection...

Fieldbus I O module - DDL

This I/O module is ATEX certified and features polyurethane housing. Ambient temperature from minimum to maximum...

Fieldbus I O module - DDL

This I/O module is ATEX certified and features polyurethane housing. Ambient temperature from minimum to maximum is 5 to 50 degrees Celsius. The operational voltage for electronics is 24V DC. The module features 16 inputs and up to 14 DDL participants.

The protection class, with plug, is IP 65. Ports include input, 8x, M12 and socket. 0.1A is the power consumption with electronics. The total current of maximum sensors is 0.5A.

Fieldbus I O module - VDS

This Field bus connection with valve system (VDS), F-design with 8 ports, active...

Fieldbus I O module - VDS

This Field bus connection with valve system (VDS), F-design with 8 ports, active...
HBM

CAN Bus I O module - 400 Mbaud | QuantumX MX471

Universal. Powerful. Flexible. There are many reasons for choosing HBM's QuantumX...

CAN Bus I O module - 400 Mbaud | QuantumX MX471

Universal. Powerful. Flexible. There are many reasons for choosing HBM's QuantumX amplifier system for data acquisition. The MX471 module enables your QuantumX system to be perfectly linked to your CAN network and to benefit from high-speed CAN and its especially high data transmission rates.

Analog output module - 400 Mbaud | QuantumX MX878

Presenting a revolutionary new product The QuantumX MX878 by HGM is a product that...

Analog output module - 400 Mbaud | QuantumX MX878

Presenting a revolutionary new product The QuantumX MX878 by HGM is a product that capitalizes quality. It features in power generation, in mechanical engineering or in research and development - data is acquired through many different channels in test and measurement applications. A definite must have for anyone seeking quality.

Multi-function I O module - 400 Mbaud | QuantumX MX879

The HBM QuantumX MX879 multi-I/O module allows you to update in real-time or online with the use of PC-based software.

The MX879 has 8 configurable analog outputs...

Multi-function I O module - 400 Mbaud | QuantumX MX879

The HBM QuantumX MX879 multi-I/O module allows you to update in real-time or online with the use of PC-based software.

The MX879 has 8 configurable analog outputs...
ifm electronic

Digital output module - AS-I, max. 31.6 V, IP20 | AC03xS series

Decentralised control of safe actuators.

AS-i SmartLine - safe output module for the control cabinet.
1 safe positively driven relay output.
4 non-safe inputs.
Safe...

Digital output module - AS-I, max. 31.6 V, IP20 | AC03xS series

Decentralised control of safe actuators.

AS-i SmartLine - safe output module for the control cabinet.
1 safe positively driven relay output.
4 non-safe inputs.
Safe decentralised control of actuators via AS-Interface.
Certification to EN 954-1/SC 4, IEC 61508/SIL3 and EN ISO13849-1/PLe.

Safe AS-i output module
The new safe AS-i SmartLine Safety at Work output module enables the connection of safe actuators to AS-Interface. The safe AS-i output module is controlled by one of the two AS-i safety monitors available as option. The user-friendly configuration and diagnostic software ASIMON V3.0 enables clear and quick assignment and logical combination of the safety-related bus components in the new function block representation under Windows.

PROFIBUS I O module - IO-Link | AC26 series

The FieldModuleDP is a compact fieldbus module custom tailored for Profibus DP with IO-Link. This product features straight incorporation to the machine with the absence of control cabinets, superior mechanical...

PROFIBUS I O module - IO-Link | AC26 series

The FieldModuleDP is a compact fieldbus module custom tailored for Profibus DP with IO-Link. This product features straight incorporation to the machine with the absence of control cabinets, superior mechanical resistance, thanks to its full plotting attribute, and data processing, configuration and diagnosis is completed through Profibus DP with the help of IO-Link. The devices data configuration and diagnosis submits to Profibus standard IEC 61158 (DP V1), enabling acyclic data transmission within the process.

This device offers an easy set-up procedure by means of GSD file, and is accessible in both digital or analouge family versions, offering a more flexible system to fit and meet various application requirements. The FieldModuleDP is the perfect answer for industrial process and manufacturing automation.

ASi I O module - M8, 26.5 - 31.6 V, IP67 | AC24 series

The AS-i CompactM8 bores featuring reliable ecolink connection manufactured by iFm presents a complete current supply consisting...

ASi I O module - M8, 26.5 - 31.6 V, IP67 | AC24 series

The AS-i CompactM8 bores featuring reliable ecolink connection manufactured by iFm presents a complete current supply consisting of a mechanical end stop that secures the O-ring from wreckage. The product is designed for resistance against shock and vibration due to its full scheming. With the new ecolink technology it prevents an erroneous attachment making it suitable for robotics, handling and assembly technology. Furthermore, this product is available as passive splitter boxes.

ASi I O module - M12, 31.6 V, IP67 | AC24 series

These devices are designed to be shock and vibration resistant. They use module and connection technology which is very effective and efficient. Other features include Bus connection for module...

ASi I O module - M12, 31.6 V, IP67 | AC24 series

These devices are designed to be shock and vibration resistant. They use module and connection technology which is very effective and efficient. Other features include Bus connection for module through M12 connector or AS-i flat cable. There is also the CompactLine module which is cased in high grade stainless steel. It is possible to achieve very quick and reliable installation since the device is integrated into the ecolink M12 connection which will protect the O-ring from destruction in case the nut is over-tightened. With the O-ring well protected, the effects of shock and vibration would not affect the device and thus users can be sure to have a reliable and long lasting gadget that will serve them effectively at all times without failing.

BIM interface module / bus - 31.5 V, IP67 | AC5225

This product is designed with an easy parameter setting for IO-Link devices, and can work with extensive diagnosis processes. This unit will...

BIM interface module / bus - 31.5 V, IP67 | AC5225

This product is designed with an easy parameter setting for IO-Link devices, and can work with extensive diagnosis processes. This unit will not lose data, and works with a master for sensors and actuators. This can link up to a sensor as needed.

The AS-i and IO-link can be used to get a link between a device and one side and a PLC or field module on another side. This may work with managing great advantages and can work with a connection for all sorts of devices. This may work with a new sensor to get energy or information transferred as needed.
{{item.name}}