I/O modules

select brand


TURCK

Ethernet/IP base I O module - -40 °C ... +70 °C | TBEN series

The first ultra-compact, digital block-I/O modules of the new TBEN-S (Small) series is one of the most technologically advanced products released by Turck. At 32mm slim and 144mm short, these fully potted IP67 modules stand apart from their competitors as they allow the assembly directly...

Ethernet/IP base I O module - -40 °C ... +70 °C | TBEN series

The first ultra-compact, digital block-I/O modules of the new TBEN-S (Small) series is one of the most technologically advanced products released by Turck. At 32mm slim and 144mm short, these fully potted IP67 modules stand apart from their competitors as they allow the assembly directly...

Fieldbus I O module - IP67 | BL67 series

The terminal bus system BL67 can be used to plan and implement tailor-made solutions for I/O applications in IP67. Gateways are available to...

Fieldbus I O module - IP67 | BL67 series

The terminal bus system BL67 can be used to plan and implement tailor-made solutions for I/O applications in IP67. Gateways are available to connect to PROFIBUS-DP, DeviceNet™, CANopen and Ethernet. Diagnostic information which can be analyzed via field bus or the software I/O ASSISTANT is provided. The electronic modules are applicable, independently from the field bus and are connected individually to the right of the gateway. The base modules are guaranteed to have a fast and reliable connection to the field devices in M8, M12 or M23 technology.

Fieldbus I O module - IP20

The product offers TURCK fieldbus I/O stations arranged according to product families. It provides product range...

Fieldbus I O module - IP20

The product offers TURCK fieldbus I/O stations arranged according to product families. It provides product range for all common fieldbus systems applied in the fields of factory and process automation. Spcifically, the product gives you fieldbus nodes for control cabinets and direct application in the field. In addition, it also offers compact stations in IP20 or IP67. The product provides tailor-made solutions for every customer's need.

Off set input module - excom® series

The Excom® is a remote I/O system created to be utilized in both Ex and non-Ex environments. It has a system that consists power supplies, gateways,...

Off set input module - excom® series

The Excom® is a remote I/O system created to be utilized in both Ex and non-Ex environments. It has a system that consists power supplies, gateways,...

Fieldbus I O module - 4.8 - 230.4 kBd, IO-Link | BL20, BL67 series

Turck is introducing new master modules for its BL20 and BL67 modular I/O systems and thus expanding its portfolio of IO-Link solutions.

Specification 1.1 with the transmission rates 4.8, 38.4 and 230.4 kBaud (COM 1, COM 2 and COM 3) is completely...

Fieldbus I O module - 4.8 - 230.4 kBd, IO-Link | BL20, BL67 series

Turck is introducing new master modules for its BL20 and BL67 modular I/O systems and thus expanding its portfolio of IO-Link solutions.

Specification 1.1 with the transmission rates 4.8, 38.4 and 230.4 kBaud (COM 1, COM 2 and COM 3) is completely...
WAGO

Digital I/O module / BACnet / decentralized / compact - 750-8xx series

Streamlined planning and implementation of building functions: WAGO’s new BACnet Controller supports MS/TP interface via standard twisted-pair cable and boasts top features, as well as simple I/O field connection.

The market trend of using BACnet in the field level is going on. As a response, WAGO has launched...

Digital I/O module / BACnet / decentralized / compact - 750-8xx series

Streamlined planning and implementation of building functions: WAGO’s new BACnet Controller supports MS/TP interface via standard twisted-pair cable and boasts top features, as well as simple I/O field connection.

The market trend of using BACnet in the field level is going on. As a response, WAGO has launched...

DIN rail I O module / rugged - -40 °C ... +70 °C | XTR 750 series

The XTR is designed to provide protection against climatic influence, vibration, impact and surge voltage, and is usually employed in harsh weather conditions found...

DIN rail I O module / rugged - -40 °C ... +70 °C | XTR 750 series

The XTR is designed to provide protection against climatic influence, vibration, impact and surge voltage, and is usually employed in harsh weather conditions found in the field of renewable energy.

It can be used in wind power, photovoltaic plants or in transformer stations. The use of the XTR reduces the space needed on the DIN rail as it eliminates the need for any additional measures of protection. In addition, it also reduces maintenance and energy costs and increases productivity. The combination of the aforementioned features makes the XTR a number one choice for feed-in management and power distribution grid monitoring.

Digital input module - 5 - 230 V | 753 series

Overview of digital input modules for the WAGO-I/O-SYSTEM. I/O modules are also available with pluggable connectors (753 Series):

2-Channel Digital Input Modules

24V,...

Digital input module - 5 - 230 V | 753 series

Overview of digital input modules for the WAGO-I/O-SYSTEM. I/O modules are also available with pluggable connectors (753 Series):

2-Channel Digital Input Modules

24V, 48V, 60V, 110V DC
24V, 42V, 120V, 230V AC
NPN/PNP, 0.2ms/3.0ms/10ms filter, diagnostics
4-Channel Digital Input Modules

5V, 24V DC
24V, 42V, 120/230V AC
NPN/PNP, 0.2ms/3.0ms/10ms/20ms/50ms filter
8-Channel Digital Input Modules

514V, 24V DC
NPN/PNP, 0.2ms/3.0ms filter
16-Channel Digital Input Modules

24VDC, NPN/PNP, 0.2ms/3.0ms filter
Ribbon cable: 24VDC, NPN/PNP, 3.0ms filter
Digital Specialty Modules

NAMUR
Pulse extension

Digital output module - max. 230 V, max. 16 A | 753 series

These digital output modules for the WAGO-I/O system come available with pluggable connectors (753 Series). The four-channel digital output modules feature 24VDC, 230V, and 0.5A/2A with broken wire/short circuit diagnostics, including 230VAC,...

Digital output module - max. 230 V, max. 16 A | 753 series

These digital output modules for the WAGO-I/O system come available with pluggable connectors (753 Series). The four-channel digital output modules feature 24VDC, 230V, and 0.5A/2A with broken wire/short circuit diagnostics, including 230VAC, SSR, and 0.5/3.0A.

The eight-channel digital output modules feature 5VDC, 24V, 0.5A, and NPN/PNP with 120/230VAC and 0.25A. It is also available in eight-channel digital input/output modules with 514VDC, 24V, 0.5/1A, and NPN/PNP.

The 16-channel digital output modules use 24VDC, 0.5A, and ribbon cable 24VDC, 0.5A. A 1-channel relay output module is available with 24VDC, 0.5A, NPN/PNP, featuring ribbon cable 24VDC, 0.5A, and NPN/PNP.

The two-channel relay output module features 230VAC, 16A with one make contact, isolated outputs for relay, and manual operation. The 0230V AC/DC has two make contacts, two changeover contacts, and no-floated isolated outputs.

Analog input module - max. 30 V | 753 series

The analog input modules for the WAGO-I/O-SYSTEM with pluggable connectors. One-channel analog input modules contain resistor bridge. The...

Analog input module - max. 30 V | 753 series

The analog input modules for the WAGO-I/O-SYSTEM with pluggable connectors. One-channel analog input modules contain resistor bridge. The two-channel analog input modules have several facilities for differential/single-ended input, 12/14/16-bit resolution. The four-channel analog input modules fitted with single-ended input, facility for 0(4)–20mA and analog specialty modules fitted with HART modules, RTD/NTC temperature measurement module, thermocouple measurement module, diagnostics and three-phase power measurement module.
CAMOZZI

Fieldbus node - 24 V, max. 50 °C | CP2, CC2, CD2

This unit is made with a 24VDC voltage and is protected with an IP65 protection class. The unit is made for EN-61326-1 and 61010-1 standards and uses an operating temperature...

Fieldbus node - 24 V, max. 50 °C | CP2, CC2, CD2

This unit is made with a 24VDC voltage and is protected with an IP65 protection class. The unit is made for EN-61326-1 and 61010-1 standards and uses an operating temperature from 0-50 degrees Celsius.

It is an aluminum unit that features a 250g weight and dimensions of 130 x 68mm. Made with 64 digital outputs and inputs with input absorption rates up to 1.5A and output absorption rates at 3A, this unit has a series of LED lights that serve to signal its functions.

It also uses a Profibus-DP, DeviceNet or CanOpen FieldBus protocol, and can use 32 to 127 nodes. It has a baud rate of 12Mbit per second on CP2, 500Kbit per second on CD2 and 1Mbit per second on CC2.
{{item.name}}