Safety modules, safety relays

select brand


HENGSTLER

Safety relay - H 469

The Hengstler 469 is a safety relay meeting the TÜV and cULus approval....

Safety relay - H 469

The Hengstler 469 is a safety relay meeting the TÜV and cULus approval....

Safety relay - H 472

This product has several great features to offer users, including seven contacts, a maximum...

Safety relay - H 472

This product has several great features to offer users, including seven contacts, a maximum...

Safety relay - H 473

Featuring five different contacts, this device can handle 6A of switching and permanent...

Safety relay - H 473

Featuring five different contacts, this device can handle 6A of switching and permanent...

Safety relay - K-RD

This product meets the requirements of RoHS with approval of cULus and TUV....

Safety relay - K-RD

This product meets the requirements of RoHS with approval of cULus and TUV. It has a maximum of 10A switching and permanent current. The ambient temperature is -10 to +80 degree Celsius. With forcibly guided contacts to EN 50205 and has type A application, its Drive is monostable as DC.

Safety relay - K-RDA

It is approved by the cULus and the TUV and contains 6 contacts with...

Safety relay - K-RDA

It is approved by the cULus and the TUV and contains 6 contacts with a 8 A maximum permanent and switching current. It has a DC monostable drive with an ambient temperature from -15 up to +70 degree Celsius with a type A application and guided contacts to EN 50205.
Leuze electronic GmbH + Co. KG

Safety relay - 24 VAC / DC | MSI-CM series

The MSI-CM Safety Relay is used as a contact extension module in accordance with DIN EN 60204‑1/VDE 0113 Part 1 for contact...

Safety relay - 24 VAC / DC | MSI-CM series

The MSI-CM Safety Relay is used as a contact extension module in accordance with DIN EN 60204‑1/VDE 0113 Part 1 for contact extension for E-Stop relays and two-hand control units. It also has five release current paths, one signaling a current path and one signaling a feedback path. The contacts release undelayed in accordance with stop category 0. Depending on the wiring and proper integration of the feedback path, a Performance Level PL e in accordance with EN ISO 13849‑1 is achieved.

Safety relay / configurable - 24 VAC / DC | MSI-DT series

LEUZE MSI-DT Series are designed and developed as safety relays with high-tech electronics that comprises their adjustable delay time that can be used for E-stop or protective-door...

Safety relay / configurable - 24 VAC / DC | MSI-DT series

LEUZE MSI-DT Series are designed and developed as safety relays with high-tech electronics that comprises their adjustable delay time that can be used for E-stop or protective-door monitoring.

It is made according to DIN EN 60204‑1/VDE 0113‑1 specifications. These series boasts safety interruption of circuits with automatic or manual start circuit. In accordance to stop category 0 and 1, the series is equipped with four release current paths. The reset button is also monitored. In cases where the relay need to be swapped, the series comes with connection terminals that can be disconnected anytime ensuring cost efficiency and high reliability.

Safety relay / multifunction - 24 VAC / DC | MSI-SR5 series

The MSI-SR5 Safety Relay is designed to allow two devices to be connected at the inputs...

Safety relay / multifunction - 24 VAC / DC | MSI-SR5 series

The MSI-SR5 Safety Relay is designed to allow two devices to be connected at the inputs using two transistor OSSDs or using it as a two-channel contact circuit. Ultimately up to two sensors can installed at a standard cut off circuit, and is appropriate for use with applications up to Performance Level PLe acc. to EN ISO 13849-1.

Safety relay / for two-hand controls - 24 VAC /DC | MSI-2H

The MSI-2H Safety Relay engineered by Leuze Electronic, performs as a link between the machine...

Safety relay / for two-hand controls - 24 VAC /DC | MSI-2H

The MSI-2H Safety Relay engineered by Leuze Electronic, performs as a link between the machine control and the standard two hand command devices. This device tracks and ensures the controlled process activation of the two dual channel buttons. It is utilized in a process environment, where automatic feed is not possible, and requires manual feeding by an operator.

Safety relay / multifunction - 24 VAC / DC | MSI-MC3x

The world class quality MSI-MC310 Safety Relay is used as an evaluation unit for magnetically coded safety system that can be used in the food, pharmaceutical...

Safety relay / multifunction - 24 VAC / DC | MSI-MC3x

The world class quality MSI-MC310 Safety Relay is used as an evaluation unit for magnetically coded safety system that can be used in the food, pharmaceutical and wood industry to monitor moveable guards such as protective doors, sliding grips or flaps. What made this one of the best is its E-STOP command which is used to open protective devices. For guards that are accessible from behind, there is a reset button that can be connected to this equipment for manual starting. The MSI-MC310 Safety Relay is made in accordance with EN ISO 13849-1 which ensures its high quality and durability.
MITSUBISHI ELECTRIC EUROPE

Safety relay - 24 VDC | QS90SR2SP

The QS90SR2SP safety relay module supports the safety I/O to be installed in the System Q controller in the event it is not economical to identify a dedicated safety controller. The module can be...

Safety relay - 24 VDC | QS90SR2SP

The QS90SR2SP safety relay module supports the safety I/O to be installed in the System Q controller in the event it is not economical to identify a dedicated safety controller. The module can be attached to a conventional System Q rack but can be used using a decentralized connection or using a conventional CC-Link network.

This setup will provide flexibility for the system. The Q690 was created to pass related safety certifications including the ISO 13849-1/2006 PL e and the EN 954 Category 4.

The system configurations of the Q690 include a conventional and safety I/O, combination of decentralized and local I/O without complicating the system and finally adding a safety I/O to the CC-Link open network as well as the non-safety devices.
{{item.name}}