V bank filters

select brand


FRANCE AIR

Fiberglass filter / V-bank / mini - 2 125 - 4 250 m³/h | FR V

Long service life: filtering surface 3 times superior to the pocket filter.
Filter burnable...

Fiberglass filter / V-bank / mini - 2 125 - 4 250 m³/h | FR V

Long service life: filtering surface 3 times superior to the pocket filter.
Filter burnable without emission of chlorine.
Low pressure drop.
Nominal flow : 2 125 to 4 250 m3/h.
Classification EN 779 : F6-F7-F9.
Frame thickness : 24 mm.
Hydrofuge glassfibre medium pleated layers or synthetic.
The filtering panels are set up in dihedron and glued.
AAF International

V-bank filter / high-capacity / mini - 12 '', 175 °F | VariCel V

AAF's VariCel V filters are high-capacity, mini-pleat filters that include increased area V-bank design, dual-density media, and light-weight but rigid construction. The VariCel...

V-bank filter / high-capacity / mini - 12 '', 175 °F | VariCel V

AAF's VariCel V filters are high-capacity, mini-pleat filters that include increased area V-bank design, dual-density media, and light-weight but rigid construction. The VariCel V filter is designed for service in HVAC installations with difficult operating conditions, such as variable air volume, turbulent airflow, repeated fan shutdown, or moderate to high humidity. The width and height dimensions are interchangeable and the filters can be installed with the pleats either vertical or horizontal without affecting performance.

Varicel V filters are available in MERV 15, 14, 13, and 11. Single and double header options. Antimicrobial available on MERV 15 and MERV 14 models.

V-bank filter - 12 ", 176 °F | VariCel VXLS

The VariCel VXLS filter delivers the desired air quality when used in systems with difficult operating conditions, such as turbulent...

V-bank filter - 12 ", 176 °F | VariCel VXLS

The VariCel VXLS filter delivers the desired air quality when used in systems with difficult operating conditions, such as turbulent airflow, repeated fan shutdown, or high humidity. The performance of the VariCel VXLS filter is not affected by difficult operating conditions, as it maintains a steady pressure drop throughout the life of the filter. The low initial resistance of the VariCel VXLS filter means less energy is required to maintain airflow.

Available in MERV 15, MERV 13, and MERV 11.

HEPA filter / V-bank - 12 ", 176 °F | BioCel VXL, BioCel VXL ULTRA

The BioCel VXL is designed to remove airborne biological contaminants from hospital critical areas and food and pharmaceutical processing plants. Rated MERV 16, it is ideal for any application where a very high...

HEPA filter / V-bank - 12 ", 176 °F | BioCel VXL, BioCel VXL ULTRA

The BioCel VXL is designed to remove airborne biological contaminants from hospital critical areas and food and pharmaceutical processing plants. Rated MERV 16, it is ideal for any application where a very high...

V-bank filter - 12 ", 176 °F | VariCel VXL

The VariCel VXL high efficiency filter is designed for service in HVAC installations with difficult operating conditions, such as variable air volume, turbulent airflow, repeated fan shutdown, or moderate to high humidity. These 8-panel filters can be used in...

V-bank filter - 12 ", 176 °F | VariCel VXL

The VariCel VXL high efficiency filter is designed for service in HVAC installations with difficult operating conditions, such as variable air volume, turbulent airflow, repeated fan shutdown, or moderate to high humidity. These 8-panel filters can be used in high velocity systems operating at up to 750 FPM. The width and height dimensions are interchangeable and the filters can be installed with the pleats either vertical or horizontal without affecting performance.


VariCel VXL pleated media is manufactured with our dual-density design of glass fiber layers for maximum dust holding capacity. The header and cell sides provide a sturdy construction that resists damage during shipping, handling, and operation. Thermoplastic separators maintain uniform spacing between pleats to allow optimal air flow and a large effective media area. Constructed of plastic, the VariCel VXL is fully incinerable.

MERV 15 and 14 models available with antimicrobial treated media. Single and double header models.

V-bank filter / high-capacity / mini - max. 2 400 cfm | AstroCel III

AAF's high capacity mini-pleat AstroCel® III filters are ideal for demanding operating conditions in critical applications. A longer service life and lower engery consumption means fewer changeouts and lower operating costs.

Multiple mini-pleat media packs, assembled into a series...

V-bank filter / high-capacity / mini - max. 2 400 cfm | AstroCel III

AAF's high capacity mini-pleat AstroCel® III filters are ideal for demanding operating conditions in critical applications. A longer service life and lower engery consumption means fewer changeouts and lower operating costs.

Multiple mini-pleat media packs, assembled into a series...
Jasun

Polypropylene filter / V-bank - F5 - F9 | NeatPleat RP series

RPS Compact Synthetic Filters F5

NeatPleat...

Polypropylene filter / V-bank - F5 - F9 | NeatPleat RP series

RPS Compact Synthetic Filters F5

NeatPleat RP (Synthetic) Rigid Bags Grade F5
Plastic Case
Fully Incinerable