Power supply transformers, instrument transformers...

select brand


CIRCUTOR

Current transformer / for energy meters - 150 - 1 500 A | MC1 series

This Power analyzer from Circutor is MC1 single phase, and is also classified as...

Current transformer / for energy meters - 150 - 1 500 A | MC1 series

This Power analyzer from Circutor is MC1 single phase, and is also classified as current transformers. The transformer range starts from 150 to 1,500A, while its secondary range is up to 250 mA. There are three ranges in the same transformer. This tool is also guaranteed to work with other MC product ranges from CIRCUTOR.

Three-phase transformer - 63 - 250 A | MC3 series

The MC3 series from Circutor is a three-phase current transformer that...

Three-phase transformer - 63 - 250 A | MC3 series

The MC3 series from Circutor is a three-phase current transformer that is made for installation above a switch. It is equipped with a transformer that has a range from 63 up to a maximum of 250 A, with a secondary current of 250 A. It is best suited for the MC series of products.

Sizing transformer / current - 40 - 4 000 A | TC series

The bar entrance type TC series from 40 to 4000A can have an internal diameter between 20.3 to...

Sizing transformer / current - 40 - 4 000 A | TC series

The bar entrance type TC series from 40 to 4000A can have an internal diameter between 20.3 to 63 mm and can have bus-bar dimensions between 25x5 mm to 30x100 mm depending on the type. The product comes with a transformer certificate sheet. The DIN rail fixing accessories are TC5 and TC6. Secondary coding types such as .../5A are on demand while .../1 A. TC12 is not available.

Current transformer / high-accuracy - 100 - 4 000 A | TCH series

The TCH Series from Circutor is a current transformer that is specially designed with...

Current transformer / high-accuracy - 100 - 4 000 A | TCH series

The TCH Series from Circutor is a current transformer that is specially designed with a narrow section to achieve high accuracy. Its internal diameter ranges from 26 mm up to 63 mm, as determined by the model type. Bus bar dimensions range from 30x10 mm up to 30x100 mm. It is capable of operating at a range of 100 up to 4000 A.

Current transformer / openable - 100 - 5 000 A | TP series

The TP Series, manufactured by Circutor, is a disassemblable current transformer that is used to...

Current transformer / openable - 100 - 5 000 A | TP series

The TP Series, manufactured by Circutor, is a disassemblable current transformer that is used to determine the measurement of rotating electric currents. This transformer is especially equipped with current type that ranges from 100 up to 5000A. It features bus bar dimensions that ranges from 20 x 30 mm up to 80 x 160 mm and a transformer certificate for reliable operations.
Contrel elettronica

Measurement transformer / current / compact - max. 100 A | TT, TTA series

Precise measurement of all the electrical parameters comes the variation of instruments from the series EMM and EMC that has been upgraded...

Measurement transformer / current / compact - max. 100 A | TT, TTA series

Precise measurement of all the electrical parameters comes the variation of instruments from the series EMM and EMC that has been upgraded with a new function. It has the ability to determine measurements from the current sensors miniaturized series of TT and TTA. It ensures an extreme accuracy even at low primary current. Additionally, these sensors are perfectly-suited for installations where there are complications of space or where power loads are unstable. The product has a very compact structure and a user-friendly technology.

Measurement transformer / current - 100 - 5000 A | TCA series

Small size and easy mounting.
Range output burden: 100A - 5000A.
High accuracy and reliability.

Measurement transformer / current / DIN rail / wall-mounted - max. 4000 A | TCB series

The TCB's different characteristics are fixing system: to wall, to cable/passing bar or to DIN rail by accessories supplied with the CT, Measuring Transformers: the short circuit on terminals or the connection...

Measurement transformer / current / DIN rail / wall-mounted - max. 4000 A | TCB series

The TCB's different characteristics are fixing system: to wall, to cable/passing bar or to DIN rail by accessories supplied with the CT, Measuring Transformers: the short circuit on terminals or the connection to earth can be achieved by the double fast-on or connecting two wires on the same terminal. And Protection Transformers: the C.T. when used as a current generator for protection relays has electrical characteristics which differ from those of the measuring transformer. Infact the measuring C.T. is expected to give a saturation of the magnetic circuit with 5P in primary currents while, in the case of protective C.T., it is necessary for the secondary current value to follow the increase in the primary current up to 10-15-20 In, so as to guarantee the intervention of the relay in the case of unforeseen breakdown current.

Current transformer / openable - max. 6000 A | TCB-A

The TCB-A is a series of current transformers that are specially made for applications that involve power...

Current transformer / openable - max. 6000 A | TCB-A

The TCB-A is a series of current transformers that are specially made for applications that involve power centers and distribution boards for plant expansion or maintenance.

The primary bar does not need to be disconnected because the unit can be installed through the core opening, providing more user-friendly set up. Terminal shields and accessories are provided, with a beam as the primary wall.

Measurement transformer / current / DIN rail / wall-mounted - max. 6000 A | TCC / TCCN

The TCC/TCCN current transformer can be fixed directly to a cable with screws, or to either a DIN rail or wall by an accessory. With this double terminal entry design, short circuit links can be fitted in the event that the...

Measurement transformer / current / DIN rail / wall-mounted - max. 6000 A | TCC / TCCN

The TCC/TCCN current transformer can be fixed directly to a cable with screws, or to either a DIN rail or wall by an accessory. With this double terminal entry design, short circuit links can be fitted in the event that the measuring instrument needs disconnected from the transformer without causing damage to the transformer. This design also allows for easier termination to the ground. When the transformer is used for protection relays as a current generator, it has electrical characteristics that make it different than measuring transformers. The measuring current transmitter is expected to give a saturation of the magnetic circuit in primary currents with 5P. With the protective transformer, it’s essential that the second current value follows the primary current increase up to 10, 15, 20, etc. This ensures relay intervention in the event of an unexpected breakdown.
EREMU

Single-phase transformer - IP-00, IP-21, EN 61558-2-1

The Eremu S.A Single Phase transformers are specifically designed for the maneuver supplement of electric charts,...

Single-phase transformer - IP-00, IP-21, EN 61558-2-1

The Eremu S.A Single Phase transformers are specifically designed for the maneuver supplement of electric charts,...

Three-phase transformer - IP-00, IP-23, EN 61558-2-1

The three-phase transformer is manufactured by Eremu SA. Created with an IP-00 and an IP-23 protection degree,...

Three-phase transformer - IP-00, IP-23, EN 61558-2-1

The three-phase transformer is manufactured by Eremu SA. Created with an IP-00 and an IP-23 protection degree,...

Three-phase auto-transformer - IP-00, IP-23, EN 61558-2-1

The three-phase autotransformer is manufactured by Eremu SA. Created with an IP-00 and an IP-23 protection degree,...

Three-phase auto-transformer - IP-00, IP-23, EN 61558-2-1

The three-phase autotransformer is manufactured by Eremu SA. Created with an IP-00 and an IP-23 protection degree,...

Toroidal transformer - 15 - 5 000 VA, 230 V | TT, TE, TCI series

The TT series is created for a 230v primary and a secondary of any voltage and power between 20v a and 5.000 va succeeding the table. However on interest, it can transform different voltages including screens,...

Toroidal transformer - 15 - 5 000 VA, 230 V | TT, TE, TCI series

The TT series is created for a 230v primary and a secondary of any voltage and power between 20v a and 5.000 va succeeding the table. However on interest, it can transform different voltages including screens, warm insurance, and so on. The standard lengths Outputs are 16 cm, 20 cm and up to 500 va 600 to 1000 w and 25 cm for higher forces. Every one of those provisions obliging little size transformer, elite, vibration, low stray field, less warming, simple to collect and for all intents and purpose zero magnetostriction clamor. The device also features shielded elecrtrostatic, strips fast connection, thermal protection, materials for high thermal class, and electromagnetic shielding. The case inside for fastening systems and thumbnail connectors and terminals are all optional and available upon request.

Three-phase auto-transformer / toroidal - 160 - 21 000 VA

21 000 VA is a Autotransformer for voltage variety wound on torodial core with graphite rollers. Single-stage standard forms:127 V from 160 to 7000 VA, 230 V...

Three-phase auto-transformer / toroidal - 160 - 21 000 VA

21 000 VA is a Autotransformer for voltage variety wound on torodial core with graphite rollers. Single-stage standard forms:127 V from 160 to 7000 VA, 230 V from 160 to 11000 VA and 400 V from 500 to 10000 VA, manual or forced helped control. for higher forces variators are joined in parallel. With three-stage standard forms: 3*230 V from 480 to 21000 VA 3*400 V, Star association, manual or force aided control. Provisions that need a nonstop variety of rotating present, single-stage or three-stage, from zero to the maximum, with high determination and a consistent level of force.
{{item.name}}