Medium-voltage fuse - 12 - 36 kV, 2 - 100 A

MV fuses are manufactured with dimensions according to DIN 43625.

They comply with standards I.E.C. 282-1. The high voltage fuse-link are mainly used for short circuit protection...

Medium-voltage fuse - 12 - 36 kV, 2 - 100 A

MV fuses are manufactured with dimensions according to DIN 43625.

They comply with standards I.E.C. 282-1. The high voltage fuse-link are mainly used for short circuit protection in high voltage installations.

The striker pin witch they are equipped further of blow-out indication, operates as device for tripping the circuit-breaker or the load-switch associated.

Expulsion Fuse Cut-Out provides a wide range of protection for over head distribution systems rated from 12kV to 36kV.

Expulsion FuseCut-Out will accommodate standard or removable button head type fuse links from 1A to 200A.

The selection of appropriate fuse links depends on the transformer type and rating.
SIBA

High-voltage fuse - max. 40.5 kV | HHD

SIBA HV-fuses are fuses for the protection of substations up to
40,5 kV.
The fuse-links of this section comply with the following national
and international standards:
• DIN 43...

High-voltage fuse - max. 40.5 kV | HHD

SIBA HV-fuses are fuses for the protection of substations up to
40,5 kV.
The fuse-links of this section comply with the following national
and international standards:
• DIN 43...

Cylindrical fuse / high-voltage - max. 24 kV | HHB

High-voltage, high-performance fuses

Power stations, substations, overhead power lines: Of the many energy utility installations that ensure our vital electricity supply, most people only take notice...

Cylindrical fuse / high-voltage - max. 24 kV | HHB

High-voltage, high-performance fuses

Power stations, substations, overhead power lines: Of the many energy utility installations that ensure our vital electricity supply, most people only take notice of the big, visible features. As far as many consumers are concerned, electricity still simply comes out of the wall. But that things are far from that simple is a story the energy utilities could tell every day.
But to prevent matters from reaching a pitch where people notice that something is wrong because the power has failed, the operators take precautions by investing in good time, and not just in the visible infrastructure. This extends from the transformer via cable and wire to the consumer. SIBA products protect this infrastructure - and thus make their own contribution to the reliability of our energy supply.

Cylindrical fuse / high-voltage - max. 24 kV | HHF

High-voltage fuse-links of size 55 x 520 mm are suitable for the
protection of power transformers used in energy distribution. Usually
they are for indoor application, but outdoor use is possible. In case of
a...

Cylindrical fuse / high-voltage - max. 24 kV | HHF

High-voltage fuse-links of size 55 x 520 mm are suitable for the
protection of power transformers used in energy distribution. Usually
they are for indoor application, but outdoor use is possible. In case of
a short circuit the fuse-link will interrupt fault currents between five
times the fuse rated current and the rated breaking current.
Standards: IEC 60282-1, NFC 64210.
The fuse tubes are made of high grade ceramic and are brown glazed
inside and outside. The contact caps are of electrolytic copper and
silver plated. For the fuse elements pure silver is used. The melting
elements are wound on a star shaped ceramic support.
For arc quenching the fuse-links are filled with quartz sand of a cer-
tain grain size.
The fuse-links are available with a temperature limiting striker or
without striker pin.

Cylindrical fuse / high-voltage - max. 13.8 kV | HHA

The new HHA type series in our HV fuse-link portfolio is
tailored to the requirements of the US market. HHA-BC fuses have
been specially designed to protect capacitor circuits indoors
and outdoors, thus offering optimum protection in case
of failure.
Rated voltage: When using a standard...

Cylindrical fuse / high-voltage - max. 13.8 kV | HHA

The new HHA type series in our HV fuse-link portfolio is
tailored to the requirements of the US market. HHA-BC fuses have
been specially designed to protect capacitor circuits indoors
and outdoors, thus offering optimum protection in case
of failure.
Rated voltage: When using a standard...

Cylindrical fuse / high-voltage - HHx

HHx Fuse-Links
High-Voltage
Special...

Cylindrical fuse / high-voltage - HHx

HHx Fuse-Links
High-Voltage
Special Fuse-Links

high voltage cylindrical fuse-link
SIEMENS Medium Voltage & Systems

HRC fuse / high-voltage / switchgear - max. 36 kV, 6.3 - 360 A | HV HRC

Ampere : min 6.3 A
VAC : min 7200.0 V

HV HRC (high-voltage high-rupturing capacity) fuse-links type 3GD are especially adequate in order to protect devices...

HRC fuse / high-voltage / switchgear - max. 36 kV, 6.3 - 360 A | HV HRC

HV HRC (high-voltage high-rupturing capacity) fuse-links type 3GD are especially adequate in order to protect devices and switchgear sections, as the standardized fuse characteristics are adapted to the interaction between the different protection equipment. They are suitable for indoor and outdoor switchgear, operation with high humidity and frequently changing condensation. Youll find detailled informations in the download on the right site.