Medium and high voltage switch disconnectors

select brand


MS Resistances

Exterior disconnect switch / high-voltage - 12 - 36 kV | SPID series

3 - Off-Load Disconnectors : up to 36 kV (On-Load on demand)
Manual or Motor Operated
Various Rated Currents & Short-Circuit Currents

Medium-voltage disconnect switch / single-pole - 12 - 36 kV | SPOD series

3 - Off-Load Disconnectors : up to 36 kV (On-Load on demand)
Manual or Motor Operated
Various Rated Currents & Short-Circuit Currents

Three-pole disconnect switch / medium-voltage - 12 - 36 kV

3 - Off-Load Disconnectors : up to 36...

Three-pole disconnect switch / medium-voltage - 12 - 36 kV

3 - Off-Load Disconnectors : up to 36 kV (On-Load on demand)
Manual or Motor Operated
Various Rated Currents & Short-Circuit Currents
RITTER

Exterior disconnect switch / high-voltage - 130 - 1 000 V | SCC series

Short Circuit Switch type SCC for all types of Electrolysis (Chlorine, Copper, nickel, zinc)
Disconnector type...

Exterior disconnect switch / high-voltage - 130 - 1 000 V | SCC series

Short Circuit Switch type SCC for all types of Electrolysis (Chlorine, Copper, nickel, zinc)
Disconnector type SCC for steel plants and Graphite-processes
Rated Voltage: 1000 V
Operating Voltage up to 130 V DC
Screw-in for copper- and aluminium busbar
High switch capacity
High electrical Strength
Maintenance free
Fail-safe and reliable
Self supporting design
No need of a supporting frame
Long lifetime

High-current disconnect switch - max. 144 kA, 1 000 V | HCC

Type tested High-Current Disconnector
Copper or aluminium screw in connection to busbar
Rated Voltage: 1000...

High-current disconnect switch - max. 144 kA, 1 000 V | HCC

Type tested High-Current Disconnector
Copper or aluminium screw in connection to busbar
Rated Voltage: 1000 V
Rated Current up to 72 kA
Special versions with up to 144 kA rated current
Special self cleaning main contacts
Available also as Y- or change-over Disconnector
Safe and visible insulating distance
Maintenance free
Fail-safe and reliable
Self supporting design
No need of a supporting frame
Long lifetime

Exterior disconnect switch / high-voltage - max. 36 kA, 1 000 V | HCC-GL

Disconnector with switching capacity
Copper screw in connection to busbar
Rated Voltage: 1000 V DC
Rated Current up to 36 kA
Special self cleaning main contacts
Type tested
Disconnecting...

Exterior disconnect switch / high-voltage - max. 36 kA, 1 000 V | HCC-GL

Disconnector with switching capacity
Copper screw in connection to busbar
Rated Voltage: 1000 V DC
Rated Current up to 36 kA
Special self cleaning main contacts
Type tested
Disconnecting distance for personal safety
High DC switching capacity
Fail-safe and reliable
Long lifetime
Area of application
Disconnectors are designed for personal safety. The type tested Ritter Disconnector type HCC-GL generate an insulating distance and can operate furthermore with a high switching capacity.

For special applications the switch can be equipped with an arrangement for horizontal arcing chamber.

The insulation level refers to normal air conditions at sea level. For installation altitude above 1000 m consider reduction of insulation level.

Exterior disconnect switch / high-voltage - max. 200 kA

Movable switch for Chorine cells
Movable switches for Chorine cells generate a short circuit and a bypassing of the current for in-line cells. The operating current will be up to 200 kA. The connecting surface "switch to cell" is from the dimension like a sheet of paper DIN-A 4. Current density, uniformly distribution of the current...

Exterior disconnect switch / high-voltage - max. 200 kA

Movable switch for Chorine cells
Movable switches for Chorine cells generate a short circuit and a bypassing of the current for in-line cells. The operating current will be up to 200 kA. The connecting surface "switch to cell" is from the dimension like a sheet of paper DIN-A 4. Current density, uniformly distribution of the current and the switching under load is an outstanding challenge.
Chlorine switches with a shaft length up to 12 meter
Fixed installed short circuit switches for Chlorine cells in-line needs shaft length up to 12 meter. The operating current and switching capacity will be up to 180 kA. Ritter delivered to many customers switches with synchronised operation and a perfect uniformly current distribution for the whole lifetime.
Movable switches for the Graphite industry
A special challenge is the dust and dirt in a Graphite plant. The switches will be moved from one graphite stove to another graphite stove and arrange the power supply by contacting a busbar at the ceiling. Ritter switches enables the contact to 240 kA rated current under dust and heat.
World biggest DC Breaker
Switching capacity with rated current 72 kA under 12 kV DC power supply, no problem for the Ritter DC-Breaker; and the insulating distance enables a safe personal safety. World record.

Medium-voltage disconnect switch - 12 - 40.5 kV, 630 - 9 000 A | RIT series

Indoor-Disconnector Type RIT
12 kV, 24 kV, 36 kV and 40,5 kV
Rated Current: 630A up to 9000A
Type tested according to IEC/EN 60694 and IEC/EN 62271-102.
Fail-safe and reliable
Safe and visible isolating distance
Small space requirements
Small maintenance efforts...

Medium-voltage disconnect switch - 12 - 40.5 kV, 630 - 9 000 A | RIT series

Indoor-Disconnector Type RIT
12 kV, 24 kV, 36 kV and 40,5 kV
Rated Current: 630A up to 9000A
Type tested according to IEC/EN 60694 and IEC/EN 62271-102.
Fail-safe and reliable
Safe and visible isolating distance
Small space requirements
Small maintenance efforts because of simple and ruggedized construction
Long lifetime
Comprehensive optional supplementary equipment

Area of application
The new Disconnector type RIT is a further development from the existing type RGT and RNT. The indoor- Disconnector is type tested according to IEC/EN 60694 and IEC/EN 62271-102. The Disconnector is suitable to open and close electric circuits, if there are negligible low currents to be disconnected or if there is no significant difference in the voltage between the electric circuits which shall be separated or the electric circuit which shall be connected. In the open position a clear visible isolating gap will be formed between all the poles of the Disconnector. The insulation level refers to normal air conditions at sea level. For installation altitude above 1000 m consider reduction of insulation level.
Ross Engineering

High-current disconnect switch - 12 - 80 kV, 400 - 600 A | GA series

This series is used for moderate to high power applications. The compact GA series high current switches are butt...

High-current disconnect switch - 12 - 80 kV, 400 - 600 A | GA series

This series is used for moderate to high power applications. The compact GA series high current switches are butt contact types and are air cylinder operated. Ratings are 12 to 80kV PK test with current level ranges of 400 or 600 amps continuous; to 10,000 amps RMS momentary, 10 cycle; and to 50,000 amps capacitor discharge, 20 uSEC. Units are designed with 2 or more SPDT auxiliary contacts or air valve type position indicators as optional accessories.

High-current disconnect switch - 27 - 150 kV, 400 - 2 000 A | GB series

Heavier-duty, high power GB series is designed with sliding multiple finger contacts. These contacts minimize power loss due to environmental contamination because of the cleaning action of...

High-current disconnect switch - 27 - 150 kV, 400 - 2 000 A | GB series

Heavier-duty, high power GB series is designed with sliding multiple finger contacts. These contacts minimize power loss due to environmental contamination because of the cleaning action of the wiping contact fingers. Standard units are for low current make or break. Arcing contacts can be added for higher current make only. They do not have an interrupting rating. Available in single pole, single throw, single or multi-pole, and double throw types, these switches are rated at 27 to 150kV PK test and 400 to 2000 amps RMS continuous; to 60,000 amps momentary, 10 cycle, and to 400,000 amps capacitor discharge, 20uSEC RC. Also available with 2 or more SPDT electrical auxiliary contacts or air valve type position indicators as optional accessories.

High-current disconnect switch - 24 - 750 kV, 400 - 8 000 A | GD series

The GD series, 80-120PSI air actuated, single pole/single or double throw switches can be water or oil cooled in some models....

High-current disconnect switch - 24 - 750 kV, 400 - 8 000 A | GD series

The GD series, 80-120PSI air actuated, single pole/single or double throw switches can be water or oil cooled in some models. Available are maximum continuous ratings of up to 8000 amps continuous in air, higher with cooling or parallelling. Contact ratings reduced to 70% when parallelled. Extremely compact for their rating, this series is available in modular block form and can be stacked in parallel for increasing current handling capabilities. Many other models are available.
{{item.name}}