Electrical insulators and bushings

select brand


CANALPLAST

Electric insulator - 0.6 - 1 kV | CPGIUNTI

This bicomponent epoxy resin is ideal for LV electric insulation. It has a high insulating power it is moisture resistant, it hardens at...

Electric insulator - 0.6 - 1 kV | CPGIUNTI

This bicomponent epoxy resin is ideal for LV electric insulation. It has a high insulating power it is moisture resistant, it hardens at room temperature allowing the immediate restart of the electric system.

The casting resin joints are very suitable for straight or branch connections of LV singlecore or multicore extruded cables. Thanks to the high insulating power of epoxy resin and to the low water absorption power, they are used above all in underground connections or even in water, ensuring a perfect seal as time goes by.
CEDASPE

Low-voltage bushing for power transformers - 1 kV, 1 000 - 1 250 A | ED 10 - ED 12 series

Voltage rating 1 kV
Current rating 1000 & 1250 A
Nominal creepage distance 80 mm
Brass...

Low-voltage bushing for power transformers - 1 kV, 1 000 - 1 250 A | ED 10 - ED 12 series

Voltage rating 1 kV
Current rating 1000 & 1250 A
Nominal creepage distance 80 mm
Brass rods& copper rods

Two design of the oil side connection:
- ED-N/12, 1250 A, Copper rod & Flat base and 2 holes M10 for traditional connection
- ED-S/12, 1250 A, Copper rod with bottom spade for rivet connection
- ED-S/10, 1000 A, Brass rod with bottom spade for rivet connection (the cheapest solution)

Low-voltage bushing for power transformers - 1 kV, 1 800 - 2 000 A | ED 18 - ED 20 series

Voltage rating 1 kV
Current rating 1800 & 2000 A
Nominal creepage distance 80 mm
Brass...

Low-voltage bushing for power transformers - 1 kV, 1 800 - 2 000 A | ED 18 - ED 20 series

Voltage rating 1 kV
Current rating 1800 & 2000 A
Nominal creepage distance 80 mm
Brass rods& copper rods

Two design of the oil side connection:
- ED-N/20, 2000 A, Copper rod & Flat base and 4 holes M16 for traditional connection
- ED-S/20, 2000 A, Copper rod with bottom spade for rivet connection
- ED-S/18, 1800 A, Brass rod with bottom spade for rivet connection (the cheapest solution)

Low-voltage bushing for power transformers - 1 kV, 3 150 - 4 000 A | ED 30 - ED 40 series

Voltage rating 1 kV
Current rating 3150 A Nominal creepage distance 80 mm
Current...

Low-voltage bushing for power transformers - 1 kV, 3 150 - 4 000 A | ED 30 - ED 40 series

Voltage rating 1 kV
Current rating 3150 A Nominal creepage distance 80 mm
Current rating 4000 A Nominal creepage distance 90 mm

Design of the oil side connection:
- ED-N/30, 3150 A, Copper rod & Flat base and 4 holes M16 for traditional connection
- ED-N/40, 4000 A, Copper rod & Flat base and 4 holes M16 for traditional connection
ELECTROTRANS

Low-voltage bushing for power transformers - 4 000 A | M55

Complete Low Voltage LV bushings for electrical distribution transformers in oil, under norms EN, DIN, UNE, etc.

Low-voltage bushing for power transformers - 3 150 A | M48

Complete Low Voltage LV bushings for electrical distribution transformers in oil, under norms EN, DIN, UNE, etc.

Low-voltage bushing for power transformers - 1 000 A | M-30

Complete Low Voltage LV bushings for electrical distribution transformers in oil, under norms EN, DIN, UNE, etc.

Low-voltage bushing for power transformers - 250 A | M-12

Complete Low Voltage LV bushings...

Low-voltage bushing for power transformers - 250 A | M-12

Complete Low Voltage LV bushings for electrical distribution transformers in oil, under norms EN, DIN, UNE, etc.

Low-voltage bushing for power transformers - 630 A | M-20

Complete Low Voltage LV bushings...

Low-voltage bushing for power transformers - 630 A | M-20

Complete Low Voltage LV bushings for electrical distribution transformers in oil, under norms EN, DIN, UNE, etc.
{{item.name}}