Multifunction calibrators, other calibrators

select brand


KISTLER

Accelerometer calibrator - ±250 g, 10 mV/g | 8676K

The device has a robust, and compact design which is duly meant for low base strain...

Accelerometer calibrator - ±250 g, 10 mV/g | 8676K

The device has a robust, and compact design which is duly meant for low base strain mass loading sensitivity, and isolated to the ground making it capable of high accuracy and high stability features. The device is applicable for accelerometer field calibrations like back to back calibration transfer standard qualifications.

Pressure calibrator / high-temperature - 20 - 250 °C, max. 250 bar | 6935A4

Calibration Manifold used for the calibration of up to 6 pressure sensors. Unit Characteristics feature several calibration ports which allow for simultaneous...

Pressure calibrator / high-temperature - 20 - 250 °C, max. 250 bar | 6935A4

Calibration Manifold used for the calibration of up to 6 pressure sensors. Unit Characteristics feature several calibration ports which allow for simultaneous calibration of up to six pressure sensors. The heated version of manifold comes with electric heating cartridges that are high performance. Applications of the Calibration Manifold include injection of pressure measurement and calibration of pressure sensor for combustion indication.

The Calibration Manifold enables customer site laboratories to Calibrate pressure sensors at varying temperatures that enhance typical operating conditions.

Accelerometer calibrator - 159,2 Hz | 8921B

This Accelerometer Calibrator Reference Shaker 159,2 Hz is a CE compliant with high...

Accelerometer calibrator - 159,2 Hz | 8921B

This Accelerometer Calibrator Reference Shaker 159,2 Hz is a CE compliant with high...
A&D COMPANY, LIMITED

Pipette accuracy tester - max. 320 g | AD-4212B-PT, AD-4212A-PT, FX-300i-PT

A&D's pipette accuracy testers provide a simple, precise, and cost-effective means for managing the accuracies of your pipettes by yourself.

The testing procedure is based the gravimetric method, which is the most commonly used test for the accuracy of variable-volume pipettes and is recommended by the ISO8655. In the gravimetric method, pipette volume is determined based on the mass...

Pipette accuracy tester - max. 320 g | AD-4212B-PT, AD-4212A-PT, FX-300i-PT

A&D's pipette accuracy testers provide a simple, precise, and cost-effective means for managing the accuracies of your pipettes by yourself.

The testing procedure is based the gravimetric method, which is the most commonly used test for the accuracy of variable-volume pipettes and is recommended by the ISO8655. In the gravimetric method, pipette volume is determined based on the mass value of the distilled water dispensed from the pipette. The high precision, accuracy, and speed of A&D's balances therefore ensure as effective testing as possible.

A&Ds pipette accuracy testers are equipped with various devices to facilitate your testing. Firstly, the evaporation trap, which prevents the evaporation of the dispensed water by maintaining high humidity inside, can minimize errors due to loss of evaporation. Secondly, the entire pipette accuracy tester set can be packed in a portable carrying case. This makes it easy to perform tests on-site, instead of collecting all the pipettes at one site for testing. Finally, the WinCT-Pipette software automatically converts mass values into volumetric values using the liquid temperature and barometric pressure previously entered. It is also possible to print an A4 or letter-size report including test conditions, data, judgment results, etc.

Three models are available depending on what volumetric range is to be measured. With A&Ds pipette accuracy tester, you can now easily and correctly screen out pipettes that need adjusting or repairing, eliminating the unnecessary costs of having all your pipettes inspected regularly by an outside contractor.
OMEGA

Temperature calibrator / humidity - +10 °C ... +50 °C, 5 - 95 %rH | RHCL-2

RHCL-2 field proven Optical Chilled Mirror (OCM) Technology features independent temperature and RH...

Temperature calibrator / humidity - +10 °C ... +50 °C, 5 - 95 %rH | RHCL-2

RHCL-2 field proven Optical Chilled Mirror (OCM) Technology features independent temperature and RH...

Multifunction calibrator - CA71

The Compact Multifunction Calibrator is a state of the art product designed and manufactured...

Multifunction calibrator - CA71

The Compact Multifunction Calibrator is a state of the art product designed and manufactured by OMEGA. It features an auto step and sweep function along with memory functions. It is designed primarily to provide simultaneous source and measure. It also exhibits voltage, pulse, current, resistance, thermo-couple, RTD and Frequency Signals.

Loop calibrator - -200 °C ... +2 300 °C | CL100MA

The CL100MA Handheld Thermocouple and Process Calibrator simulates temperature or process...

Loop calibrator - -200 °C ... +2 300 °C | CL100MA

The CL100MA Handheld Thermocouple and Process Calibrator simulates temperature or process...

Multifunction calibrator / portable - -200 °C ... +2 500 °C | CL310

The CL310multi-function calibrator features high accuracy (0.015%), allows user to measure...

Multifunction calibrator / portable - -200 °C ... +2 500 °C | CL310

The CL310multi-function calibrator features high accuracy (0.015%), allows user to measure and simulate T/Cs, RTDs, resistance, voltage, current, pressure and frequency (with programmable simulate modes), and directly input custom RTD coefficients. 21 data points per instrument can be stored, and the unit can test for pass/fail criteria. Software is included.

Pressure calibrator / digital - RS232, 0.0025 % | CL3001

This 0.0025% accurate material works on voltage,...

Pressure calibrator / digital - RS232, 0.0025 % | CL3001

This 0.0025% accurate material works on voltage, current and pressure ratings and is made with a USB and RS232 control setup.

It uses an isolated measurement channel.
{{item.name}}