Laboratory stirrers, laboratory shakers

select brand


KW EP MECA

Magnetic agitator / laboratory

The magnetic stirrer has four 7 to 11 watt motors with a maximum speed...

Magnetic agitator / laboratory

The magnetic stirrer has four 7 to 11 watt motors with a maximum speed of 1500 rpm. These spin perfectly balanced bipolar magnets weighing from 30 to 80 grams. Each motor has its own on-off switch and speed control.
Design and technical developments are envisaged.

Laboratory agitator - Minimix

The Minimix laboratory mixer is driven by a 12 volt DC motor. The variable speed control covers...

Laboratory agitator - Minimix

The Minimix laboratory mixer is driven by a 12 volt DC motor. The variable speed control covers the range from 0 to 300 rpm.
Maximum Power: 10 watts
The housing has an on-off switch and an electrical connection.
The device comes with a 220/110 V to 12 VDC transformer, the motor and the PVC housing.
Design and technical developments are envisaged.

Laboratory agitator

EP MECA offers a complete line of stirring blades.
We can design and...

Laboratory agitator

EP MECA offers a complete line of stirring blades.
We can design and...
AUTOCLAVE ENGINEERS/Parker Hannifin

Vertical agitator / magnetic-drive / laboratory - max. 3 600 rpm, 372 bar | 3050 MagneDrive® III series

MAG III MagneDrive agitator makes use of rare earth magnets to allow packless blending at great speed where the fluids have high viscosity . It operates...

Vertical agitator / magnetic-drive / laboratory - max. 3 600 rpm, 372 bar | 3050 MagneDrive® III series

MAG III MagneDrive agitator makes use of rare earth magnets to allow packless blending at great speed where the fluids have high viscosity . It operates at Continuous, high speed which does not shut down in mid-reaction to change failed packing. The outer rotating magnet which is connected with a motor employs strong attractive force to rotate the inner magnet which results in rotating the shaft. The adulteration free mixing design helps in avoiding shaft packing. To avoid friction lubrication is needed. It is well packed system with no leakage which allows even very sensitive fluids to go through the process.

Vertical agitator / magnetic-drive / laboratory - max. 3 600 rpm, 414 bar | 075 MagneDrive® II series

The 075 Model is a magnetic-drive vertical agitator by Autoclave Engineers. It is specially...

Vertical agitator / magnetic-drive / laboratory - max. 3 600 rpm, 414 bar | 075 MagneDrive® II series

The 075 Model is a magnetic-drive vertical agitator by Autoclave Engineers. It is specially built suitable for automatic operation. The unit comes with higher speeds and higher viscosity fluids. It also uses a rare earth magnets and permitting pack-less mixing. In addition, the framework features zero leakage, and continuous operation at high speed performance.

H agitator / magnetic-drive / laboratory - 344 - 414 bar, +454 °C ... +510 °C | MAG075 MagneDrive®

The MagneDrive® agitator is recognized worldwide as a highly efficient method of promoting chemical reactions and catalyst testing among gases, liquids,...

H agitator / magnetic-drive / laboratory - 344 - 414 bar, +454 °C ... +510 °C | MAG075 MagneDrive®

The MagneDrive® agitator is recognized worldwide as a highly efficient method of promoting chemical reactions and catalyst testing among gases, liquids,...

Rotary operated agitator / vertical / magnetic-drive / laboratory - 415 bar, +343 °C | 1.5001 MagneDrive® II series

MagneDrive II agitators use rare earth magnets, permitting packless mixing at higher speeds in larger vessels and with higher viscosity fluids. Outer drive magnets, rotated by a motor-driven...

Rotary operated agitator / vertical / magnetic-drive / laboratory - 415 bar, +343 °C | 1.5001 MagneDrive® II series

MagneDrive II agitators use rare earth magnets, permitting packless mixing at higher speeds in larger vessels and with higher viscosity fluids. Outer drive magnets, rotated by a motor-driven belt, exert powerful attraction on the encapsulated inner magnet assembly. As the outer drive magnets are rotated, the inner magnets are actuated, resulting in rotation of the agitator shaft.

Contamination-free mixing- Packless design eliminates shaft packing and need for lubrication.

Zero leakage to atmosphere- The MagneDrive II is a sealed system, closed to the atmosphere, so even sensitive fluids can be processed safely. Continuous, high speed operation- No need to shut down in mid-reaction to change failed packing.

Rotary operated agitator / vertical / magnetic-drive / laboratory - max. 455 bar, +343 °C | 1.5002 MagneDrive® II series

MagneDrive II agitators use rare earth magnets, permitting packless mixing at higher speeds in larger vessels and with higher viscosity fluids. Outer drive magnets, rotated by a motor-driven...

Rotary operated agitator / vertical / magnetic-drive / laboratory - max. 455 bar, +343 °C | 1.5002 MagneDrive® II series

MagneDrive II agitators use rare earth magnets, permitting packless mixing at higher speeds in larger vessels and with higher viscosity fluids. Outer drive magnets, rotated by a motor-driven belt, exert powerful attraction on the encapsulated inner magnet assembly. As the outer drive magnets are rotated, the inner magnets are actuated, resulting in rotation of the agitator shaft.

Contamination-free mixing- Packless design eliminates shaft packing and need for lubrication.

Zero leakage to atmosphere- The MagneDrive II is a sealed system, closed to the atmosphere, so even sensitive fluids can be processed safely. Continuous, high speed operation- No need to shut down in mid-reaction to change failed packing.
{{item.name}}