Hydrogen analyzers (H2)

select brand


Hach

Hydrogen analyzer - ORBISPHERE 3654

3654 handheld analyzer measures accurately nitrogen (N2) or hydrogen (H2) in either dissolved or in gas phase. Measurements are...

Hydrogen analyzer - ORBISPHERE 3654

3654 handheld analyzer measures accurately nitrogen (N2) or hydrogen (H2) in either dissolved or in gas phase. Measurements are not affected by the presence of other gases. Stores up to 500 measurements. Rechargeable batteries allow up to 15 hours operation in continuous measuring mode.

* N2 or H2 readings in less than 3 minutes
* Works with an Orbisphere patented thermal conductivity (TC) sensor
* Measurements are not affected by the presence of other gases
H2scan

Hydrogen analyzer / in-line / process - HY-OPTIMA 2700AS

Sensor Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen by volume at 1 ATM

Response Time: T90 < 30 sec
Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
±...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2700AS

Sensor Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen by volume at 1 ATM

Response Time: T90 < 30 sec
Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
±...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2700

Performance

Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM

Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
± 0.2% absolute for 0.5 to 10% H2
± 0.4%...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2700

Performance

Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM

Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
± 0.2% absolute for 0.5 to 10% H2
± 0.4%...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2720

Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM

Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Accuracy: ± 3% of reading + 2000 ppm

Interface Options
Input Voltage Range: 90 VAC to 240 VAC
Input Power: 15W
Analog...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2720

Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM

Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Accuracy: ± 3% of reading + 2000 ppm

Interface Options
Input Voltage Range: 90 VAC to 240 VAC
Input Power: 15W
Analog...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2730

Performance

Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM on a volume basis in a single or multicomponent gas background

Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
±...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2730

Performance

Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM on a volume basis in a single or multicomponent gas background

Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
±...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2740

Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM on a volume basis in a single or multi-component gas background

Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
±...

Hydrogen analyzer / in-line / process - HY-OPTIMA 2740

Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen at 1 ATM on a volume basis in a single or multi-component gas background

Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
±...
DKK-TOA

Hydrogen analyzer / portable - 0 - 10 ppm | DH-35A

Fast response with membrane type polarographic electrode
Highly sensitive measurement...

Hydrogen analyzer / portable - 0 - 10 ppm | DH-35A

Fast response with membrane type polarographic electrode
Highly sensitive measurement with μg/L
Atmospheric calibration method & hydrogen std. gas not required
AC/DC batteries 2-way power source
Equipped with flow-through cell &analogue output cable(std.)
Meas. range: 0.0ppb~10.00ppm
{{item.name}}