Atomic absorption spectrometers, atomic fluorescence spectrometers

select brand


Buck Scientific

GFAAS spectrometer / graphite furnace atomic absorption - 220

The model 220 GF accessory has a Unique Furnace Design with the latest technology in PPB level analyses by graphite furnace AA. This is a completely integrated device that uses an innovative and unique technology in a powerful module....

GFAAS spectrometer / graphite furnace atomic absorption - 220

The model 220 GF accessory has a Unique Furnace Design with the latest technology in PPB level analyses by graphite furnace AA. This is a completely integrated device that uses an innovative and unique technology in a powerful module. The changeover between the furnace and flame heads is permitted through quick-mount design.

The power supply in the furnace has the capacity to generate temperatures of up to 3000 C in less than a Sec. It provides superior sensitivity in refractory elements and carbide forming metals. The on-board firmware gives the chemist complete control of all the aspects of the analysis. The operator is allowed to program Gas flows (external, internal, mini-internal and auxiliary are standard), data collection (integrated, real-time, peak height or absorbance area) and electronic parameters for the hollow cathode lamps and the various background correction routines for optimum results.
Aurora Instruments

Flame atomic absorption spectrometer / FAAS - TRACE AI1200

Aurora has built a reputation as an industry leader manufacturing atomic absorption spectrometers and atomic fluorescence spectrometers. Thanks to its many customizable options, the TRACE AI1200 is also one of the most versatile atomic absorption spectrometers on the market today. What...

Flame atomic absorption spectrometer / FAAS - TRACE AI1200

Aurora has built a reputation as an industry leader manufacturing atomic absorption spectrometers and atomic fluorescence spectrometers. Thanks to its many customizable options, the TRACE AI1200 is also one of the most versatile atomic absorption spectrometers on the market today. What started out as a good idea has since been developed into a remarkable analytical instrument. In an industry that is becoming increasingly specialized, it is easy to recognize the advantages of an analytical instrument that offers so many possibilities in such a small space. We invite you to download the brochure and examine the many features available compared to other atomic absorption spectrometers. With true double beam optics, a transversely heated graphite furnace tube (optional) and a host of automated safety features the TRACE AI1200 Atomic Absorption Spectrometer offers a cost-effective and reliable solution for your elemental analysis requirements. Combining the TRACE AI1200 atomic absorption spectrometer with our unique Vapour Hydride Generator (F/VG or F/GF/VG configurations) allows extremely low detection limits to be achieved.

Atomic absorption spectrometer / AAS - TRACE 1300 series

Current industry demands require that elemental analyses embody higher precision, higher sensitivity, and lower detection limits than ever before. Aurora has built a reputation as...

Atomic absorption spectrometer / AAS - TRACE 1300 series

Current industry demands require that elemental analyses embody higher precision, higher sensitivity, and lower detection limits than ever before. Aurora has built a reputation as an industry leader in atomic absorption and atomic fluorescence spectrometry. Building on this success, Aurora is pleased to introduce their newest addition to their line of atomic absorption spectrometers - the TRACE 1300. This workstation generates faster results while providing superior accuracy. The TRACE 1300 Atomic Absorption Spectrometer is a high performance atomic absorption spectrometer (AAS) designed for many applications requiring a high quality precision instrument such as food & drug safety and medical applications.

Atomic fluorescence spectrometer / AFS - LUMINA 3300

The LUMINA 3300 Atomic Fluorescence Spectrometer provides elemental analysis solutions for sub trace detection of hydride-forming elements. The unique vapour/hydride generator provides enhanced sensitivities...

Atomic fluorescence spectrometer / AFS - LUMINA 3300

The LUMINA 3300 Atomic Fluorescence Spectrometer provides elemental analysis solutions for sub trace detection of hydride-forming elements. The unique vapour/hydride generator provides enhanced sensitivities and reduced interferences for parts per trillion (ppt) detection of Mercury (Hg), Arsenic (As), Cadmium (Cd), Zinc (Zn), Bismuth (Bi), Selenium (Se), Tellurium (Te), Antimony (Sb), Tin (Sn), Germanium (Ge), and Lead (Pb).

The LUMINA 3300 Atomic Fluorescence Spectrometer is ideal for elemental analysis in various research sectors, including; environmental, agricultural, geological, metallurgical, pharmaceutical, clinical and petrochemical. It is capable of acting as a mercury analyzer while also carrying out elemental analysis of all hydride-forming elements.
PG INSTRUMENTS LIMITED

Atomic absorption spectrometer / AAS - AA500G

AA500G


The Instrument is equipped with a Graphite Furnace Atomiser only. The Graphite head is fixed into the optical path to maximise performance and eliminate drift.




The instrument is equipped with a Graphite Furnace Atomiser only. The graphite head is fixed...

Atomic absorption spectrometer / AAS - AA500G

AA500G


The Instrument is equipped with a Graphite Furnace Atomiser only. The Graphite head is fixed into the optical path to maximise performance and eliminate drift.




The instrument is equipped with a Graphite Furnace Atomiser only. The graphite head is fixed into the optical path to maximise performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique.

Standard Features
Embedded PC system built into the instrument as standard on all configurations. Pre-installed UV-Win Pro software, user manuals, cook book and Windows 7 professional operating system.
UV-Win Pro software provides full control of the instrument and autosampler with easy method change for each technique.
Automatic 8 Hollow Cathode lamp turret controlled and optimised by the AA-Win Pro software. Operating lamp current and warm-up lamp current can be individually controlled to eliminate drift commonly associated with lamp warming.

Atomic absorption spectrometer / AAS - AA500F

AA500F


The instrument is equipped with a flame atomiser only. Three flame options are available including Air/Acetylene N2O/Acetylene and Air/LPG (Natural gas).




The instrument is equipped with a flame atomiser only. The positioning of which is fully controlled by the embedded computer...

Atomic absorption spectrometer / AAS - AA500F

AA500F


The instrument is equipped with a flame atomiser only. Three flame options are available including Air/Acetylene N2O/Acetylene and Air/LPG (Natural gas).




The instrument is equipped with a flame atomiser only. The positioning of which is fully controlled by the embedded computer system and AA-Win Pro software. Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (Natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection.

Standard Features

Embedded PC system built into the instrument as standard on all configurations. Pre-installed UV-Win Pro software, user manuals, cook book and Windows 7 professional operating system.
UV-Win Pro software provides full control of the instrument and autosampler with easy method change for each technique.
Automatic 8 Hollow Cathode lamp turret controlled and optimised by the AA-Win Pro software. Operating lamp current and warm-up lamp current can be individually controlled to eliminate drift commonly associated with lamp warming.

Atomic absorption spectrometer / AAS - AA500FG

AA500FG


The instrument is equipped with both Flame Atomiser and Graphite Atomiser. Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile AA-Win Pro software.




The instrument is equipped with both Flame Atomiser...

Atomic absorption spectrometer / AAS - AA500FG

AA500FG


The instrument is equipped with both Flame Atomiser and Graphite Atomiser. Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile AA-Win Pro software.




The instrument is equipped with both Flame Atomiser and Graphite Atomiser. Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile AA-Win Pro software.

The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique.
The flame atomiser position is fully controlled by the embedded computer system and AA-Win Pro software.

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (Natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection.

Atomic fluorescence spectrometer / AFS - AF402

AF402 Simultaneous Atomic Fluorescence Spectrophotometer



The Atomic Fluorescence Spectroscopy technique is used to measure samples containing both hydride forming elements and mercury in a variety of analytical sectors.




The Atomic Fluorescence...

Atomic fluorescence spectrometer / AFS - AF402

AF402 Simultaneous Atomic Fluorescence Spectrophotometer



The Atomic Fluorescence Spectroscopy technique is used to measure samples containing both hydride forming elements and mercury in a variety of analytical sectors.




The Atomic Fluorescence Spectroscopy technique is used to measure samples containing both hydride forming elements and mercury in a variety of analytical sectors. Due to its design and functionality, the instrument offers enhanced sensitivity, reduced interference and excellent limits of detection (ppt).

The AF402 is an ideal instrument for elemental analysis in various market and research industries including:

Agriculture
Food and Beverage
Public Health
Clinical
Pharmaceutical
Geological
Metallurgical
Petrochemical

Standard features
Light Source
High Intensity Hollow Cathode lamps for greater intensity and stability.
Up to three lamps can be installed for simultaneous analysis.
All lamps are uniquely data coded offering important information to the PF Win operating software.