Switchgear

select brand


SIEMENS Medium Voltage & Systems

Primary switchgear / medium-voltage / air-insulated / metal-clad - 17.5 - 24 V, 2.5 - 4 kA | NXAIR series

Type-tested, IEC62271-200, metal-clad, loss of service continuity category: LSC 2B; partition class: PM; internal arc classification: IAC A FLR ≤ 50 kA 1s
Air...

Primary switchgear / medium-voltage / air-insulated / metal-clad - 17.5 - 24 V, 2.5 - 4 kA | NXAIR series

Type-tested, IEC62271-200, metal-clad, loss of service continuity category: LSC 2B; partition class: PM; internal arc classification: IAC A FLR ≤ 50 kA 1s
Air as insulating medium is always available
Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches inside the panel
Single busbar, Duplex-switchgear
Withdrawable vacuum circuit-breaker
Withdrawable vacuum contactor
Platform concept worldwide, local manufacturing presence
Use of standardized devices
Maximum security of operation by self-explaining operating logic
Maintenance interval > 10 years

Primary switchgear / medium-voltage / compact / metal-clad - max. 24 V, max. 2 kA | 8BT1

Type-tested, metal-enclosed
Vacuum circuit-breaker withdrawable
Easy...

Primary switchgear / medium-voltage / compact / metal-clad - max. 24 V, max. 2 kA | 8BT1

Type-tested, metal-enclosed
Vacuum circuit-breaker withdrawable
Easy operation, maintenance and cable access from front
Automatic metal protection shutter
Max. operating safety by self-explanatory logical operating elements

Primary switchgear / medium-voltage / air-insulated - 24 - 36 kV, max. 2.5 kA | 8BT2

Type-tested, LSC2B-PM type IAC switchgear according to IEC 62271-200
Air as insulating medium is always available
Evidence of the making...

Primary switchgear / medium-voltage / air-insulated - 24 - 36 kV, max. 2.5 kA | 8BT2

Type-tested, LSC2B-PM type IAC switchgear according to IEC 62271-200
Air as insulating medium is always available
Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches inside the panel
Vacuum circuit-breaker withdrawable on truck
Withdrawable voltage transformers with primary fuses in connection compartment
Easy operation amd maintenance
Max.security of operation by self-explaining operating logic
Use of high-quality standard components
Maintenance interval >10 years

Primary switchgear / medium-voltage / vacuum / air-insulated - 7.2 - 17.5 kV, max. 3.6 kA | SIMOPRIME

Type-tested, LSC2B-PM, IAC switchgear
as per IEC 62271-200
Vacuum...

Primary switchgear / medium-voltage / vacuum / air-insulated - 7.2 - 17.5 kV, max. 3.6 kA | SIMOPRIME

Type-tested, LSC2B-PM, IAC switchgear
as per IEC 62271-200
Vacuum circuit-breaker withdrawable on truck
Customer benefits:
- Peace of Mind
- Saves Lives
- Increases Productivity and
- Saves Money

Secondary switchgear / medium-voltage / metal-clad / gas-insulated - max. 24 kV, 1.25 kA | SIMOSEC

Up to 24 kV, 25 kA, 1250 A busbar, 1250 A feeders
Metal-enclosed
Single busbar
Air-insulated...

Secondary switchgear / medium-voltage / metal-clad / gas-insulated - max. 24 kV, 1.25 kA | SIMOSEC

Up to 24 kV, 25 kA, 1250 A busbar, 1250 A feeders
Metal-enclosed
Single busbar
Air-insulated technology combined with a gas-insulated switching function
Factory-assembled, type-tested switchgear according to IEC 62271-200
Customer Benefit:
- Compactness
- Personal safety
- Operational safety, reliability
- Cost-efficient, Ecological
CIERRE

Switchgear

Cierre electrical panel assemblies are suitable for industrial automation, railway, energy conversion and distribution, renewable energy, robotics, oil and gas. They have a production area of 2,000 square meters. They...

Switchgear

Cierre electrical panel assemblies are suitable for industrial automation, railway, energy conversion and distribution, renewable energy, robotics, oil and gas. They have a production area of 2,000 square meters. They feature a well-equipped laboratory for testing and burning. Cierre can provide harnesses as per UL standards for the American market and as per CSA standards for the Canadian market. The electric panels are full with display, inverter, sensors, PLC, actuators, logic control and buttons.

Parts of only major manufacturers like Siemens, Omron, ABB, Sma, Schneider, Rittal, Santerno, R&B and others are used by Cierre. They allow manufacturing of panels as per certification needs. They are suitable for use in ATEX Zone 1 and Zone 2. The department can manufacture about 6,000 electrical panels in a year.
Driescher

Secondary switchgear / medium-voltage / air-insulated - 12 kV, 630 A | W 12 series

The W 12 Series, manufactured by Driesher, is an air insulated medium voltage...

Secondary switchgear / medium-voltage / air-insulated - 12 kV, 630 A | W 12 series

The W 12 Series, manufactured by Driesher, is an air insulated medium voltage switch gear integrated with a rated voltage of 12 kV and a maximum rated current of 630 amperes. The medium voltage switch gear is used to cut off the power in various parts of an electricity distribution network.

Secondary switchgear / medium-voltage / air-insulated - 24 kV, 1 250 A | W 24 series

The W 24 Series, manufactured by Driesher, is an air insulated medium voltage...

Secondary switchgear / medium-voltage / air-insulated - 24 kV, 1 250 A | W 24 series

The W 24 Series, manufactured by Driesher, is an air insulated medium voltage switch gear integrated with a rated voltage of 24 kV and a maximum rated current of 1250 amperes. The medium voltage switch gear is used to cut off the power in various parts of an electricity distribution network.

Secondary switchgear / medium-voltage / air-insulated - 12 - 24 kV, 630 A | D 12, D 24 series

DRIESCHER air-insulated medium-voltage switchgears are a Type D 12...

Secondary switchgear / medium-voltage / air-insulated - 12 - 24 kV, 630 A | D 12, D 24 series

DRIESCHER air-insulated medium-voltage switchgears are a Type D 12 – 507519. They are rated for 12 kv voltage and 630 A current.

The Type D 24 – 601119 is also an option and they are rated for 24 kv voltage and 630 A current.

Secondary switchgear / medium-voltage / air-insulated - 24 kV, 630 A | F 24 series

Driescher presents type F24 air-insulated medium voltage switchgears. The metal enclosed switchgears...

Secondary switchgear / medium-voltage / air-insulated - 24 kV, 630 A | F 24 series

Driescher presents type F24 air-insulated medium voltage switchgears. The metal enclosed switchgears can handle a range of applications such as compact cable ring units and complex power distribution applications. Models include type F24 - 606519-27, type F24 - 756519-27 and type F24 - 906519. All models have rated voltage of 24 kV and rated current of 630 A.

Secondary switchgear / medium-voltage / air-insulated - 12 - 36 kV | EK series

The Driescher insulators contain switchpanels that are of medium-voltage designs. These apparatuses...

Secondary switchgear / medium-voltage / air-insulated - 12 - 36 kV | EK series

The Driescher insulators contain switchpanels that are of medium-voltage designs. These apparatuses are designed and manufactured to comply with a wide array of customer and application requirements. They can be availed with the withdrawable type WEL, and withdrawable type that has 2 or 3 compartment layouts. The voltage range of the insulators are 12 kV, 24 kV, and 36 kV.