Liquid analyzers: hardness, salinity

select brand


Hanna Instruments

Waterproof salinity measuring device - 0.15 - 300 g/l | HI 931102

Tutorial messages on LCD display
Calibration reminder
Displays parameter and temperature readings simultaneously
Automatic calibration
Dual-level LCD


HANNA® has designed this waterproof salinity meter for use in...

Waterproof salinity measuring device - 0.15 - 300 g/l | HI 931102

Tutorial messages on LCD display
Calibration reminder
Displays parameter and temperature readings simultaneously
Automatic calibration
Dual-level LCD


HANNA® has designed this waterproof salinity meter for use in...

Water hardness measuring device - 0 - 3 pNa | HI 98202

800 hours of continuous use
Easy one point calibration


The pNa is an easy to use and inexpensive instrument for determining water hardness or softness. The hardness of water is due to the presence of magnesium and calcium. These make washing difficult, wastes soap, and creates unpleasant...

Water hardness measuring device - 0 - 3 pNa | HI 98202

800 hours of continuous use
Easy one point calibration


The pNa is an easy to use and inexpensive instrument for determining water hardness or softness. The hardness of water is due to the presence of magnesium and calcium. These make washing difficult, wastes soap, and creates unpleasant scum and scale deposits. With a zeolite system, the calcium and magnesium ions are substituted on a one-to-one basis with sodium ions from a conditioning resin. Once all the sodium ions are exhausted, the resin has to be regenerated.

A common but inaccurate way to determine when to change resin is to estimate the volume of water that goes through the softener and guessing when to change the resin! Even though this may work in some cases, it fails in most since the sodium content of feed water is never constant. As a result, either the resin is regenerated too early and wastes resources, or too late, risking damage due to scaling.

With the pNa, you can measure the sodium content of feed and exit water in seconds. When the resin is exhausted of sodium, there will be no exchange and the pNa will read the same value at the two ends. Only then should the resin be changed.
ATAGO

Salinity measuring device - PAL-ES series

Using a conductivity method of testing,...

Salinity measuring device - PAL-ES series

Using a conductivity method of testing, the ATAGO Digital Salt-Meter is used for measuring the level of salinity in a solution of soluble materials.

Water hardness analyzer / in-line - 0.05 - 25 °dH | Testomat 2000®

For more than 40 years, our Testomat® instruments have been renowned for providing reliable water hardness measurements to monitor softening plants and to protect downstream plants and processes. The reason is plain to see:

...

Water hardness analyzer / in-line - 0.05 - 25 °dH | Testomat 2000®

For more than 40 years, our Testomat® instruments have been renowned for providing reliable water hardness measurements to monitor softening plants and to protect downstream plants and processes. The reason is plain to see:

...

Water hardness analyzer / in-line - 0.02 - 3 °dH | Testomat® 808

Testomat® 808 has been designed for use in the field of water treatment (e.g. osmosis plants, electroplating, large boiler plants, laundries, canteen kitchens). The feed water must be clear, colorless, and free of undissolved particles. The instrument is...

Water hardness analyzer / in-line - 0.02 - 3 °dH | Testomat® 808

Testomat® 808 has been designed for use in the field of water treatment (e.g. osmosis plants, electroplating, large boiler plants, laundries, canteen kitchens). The feed water must be clear, colorless, and free of undissolved particles. The instrument is...

Water hardness analyzer / in-line - 0.05 – 0.5 °dH | Testomat 2000® CAL

The Testomat 2000 ® CAL corresponds in function and suitability to the Testomat 2000®, but has an additional calibration...

Water hardness analyzer / in-line - 0.05 – 0.5 °dH | Testomat 2000® CAL

The Testomat 2000 ® CAL corresponds in function and suitability to the Testomat 2000®, but has an additional calibration...

Water hardness analyzer / in-line - 0.05 – 0.5 °dH| Testomat 2000® CN DUO

Testomat 2000® CN DUO for two parameters and with Chinese menu language
Two-line LCD display for text display in English and Mandarin and selfexplanatory,...

Water hardness analyzer / in-line - 0.05 – 0.5 °dH| Testomat 2000® CN DUO

Testomat 2000® CN DUO for two parameters and with Chinese menu language
Two-line LCD display for text display in English and Mandarin and selfexplanatory,...

Carbonate hardness monitoring device - 2 - 150 °KH | Titromat® KH

Titromat® KH is used for automatically determining and monitoring the
carbonate...

Carbonate hardness monitoring device - 2 - 150 °KH | Titromat® KH

Titromat® KH is used for automatically determining and monitoring the
carbonate...
{{item.name}}