Noise dosimeters, Vibration dosimeters

select brand


CESVA

Noise analyzer-dosimeter / personal - 2003/10/CE | DC112

The DC112 is a high performance dosimeter, the ideal instrument for measuring noise according to Directive 2003/10/CE, which adapts to technical progress the regulation on the health and safety requirements regarding the exposure of workers to the risks arising from noise.

The DC112 enables...

Noise analyzer-dosimeter / personal - 2003/10/CE | DC112

The DC112 is a high performance dosimeter, the ideal instrument for measuring noise according to Directive 2003/10/CE, which adapts to technical progress the regulation on the health and safety requirements regarding the exposure of workers to the risks arising from noise.

The DC112 enables you to measure simultaneously all the parameters needed to assess the levels of noise to which workers are exposed with and without hearing protectors (SNR, HML and Octaves). The DC112, besides measuring the equivalent level with A and C frequency weightings [ LAt, LCt ] (SNR and HML method), simultaneously carries out a real time frequency analysis with or without A frequency weighting and by octave bands from 63 Hz to 8 kHz (Octave method). And, of course, also the Peak Level with C frequency weighting [LCpeak].

The DC112 enables you to assess and measure exposure to noise and also brings you all the data needed to inform and train workers with regard to the significance and potential risks arising from the results of the measurement and assessment.

Moreover, It helps you to design and run a reduction programme and to choose the most suitable hearing protectors.

Noise analyzer-dosimeter / personal - ANSI S1.25-1991 class 2 | DC112a

The DC112a is an ANSI S1.25-1991 class 2 compliant dosimeter and enables of the health and safety protection of workers against risks arising from exposure to noise to be evaluated according to OSHA, MSHA, DoD, ACGIH, NIOSH,...

Noise analyzer-dosimeter / personal - ANSI S1.25-1991 class 2 | DC112a

The DC112a is an ANSI S1.25-1991 class 2 compliant dosimeter and enables of the health and safety protection of workers against risks arising from exposure to noise to be evaluated according to OSHA, MSHA, DoD, ACGIH, NIOSH,...

Noise dosimeter / personal - 2003/10/CE | DC112d

The DC112d is a high performance dosimeter, the ideal instrument for measuring noise according to Directive 2003/10/CE, which adapts to technical progress the regulation on the health and safety requirements regarding the exposure...

Noise dosimeter / personal - 2003/10/CE | DC112d

The DC112d is a high performance dosimeter, the ideal instrument for measuring noise according to Directive 2003/10/CE, which adapts to technical progress the regulation on the health and safety requirements regarding the exposure of workers to the risks arising from noise.

The DC112d enables you to measure simultaneously all the parameters needed to assess the levels of noise to which workers are exposed with and without hearing protectors (SNR and HML). The DC112d, measures the equivalent level with A and C frequency weightings [ LAt, LCt ] (SNR and HML method). And, of course, also the Peak Level with C frequency weighting [LCpeak].

The DC112 enables you to assess and measure exposure to noise and also brings you all the data needed to inform and train workers with regard to the significance and potential risks arising from the results of the measurement and assessment.

Noise dosimeter / personal - ANSI S1.25-1991 class 2 | DC112k

The DC112k is an ANSI S1.25-1991 class 2 compliant dosimeter and enables of the health and safety protection of workers against risks arising from exposure to noise to be evaluated according to OSHA, MSHA, DoD, ACGIH, NIOSH,...

Noise dosimeter / personal - ANSI S1.25-1991 class 2 | DC112k

The DC112k is an ANSI S1.25-1991 class 2 compliant dosimeter and enables of the health and safety protection of workers against risks arising from exposure to noise to be evaluated according to OSHA, MSHA, DoD, ACGIH, NIOSH,...
Metra

Triaxial vibration meter - 0.4 - 10 000 Hz | VM30-H

* For hand-arm vibration measurement to ISO 5349, whole-body vibration to ISO 2631, BS 6841 or ANSI S3.18 and ship vibration to ISO 6954
* Machine...

Triaxial vibration meter - 0.4 - 10 000 Hz | VM30-H

* For hand-arm vibration measurement to ISO 5349, whole-body vibration to ISO 2631, BS 6841 or ANSI S3.18 and ship vibration to ISO 6954
* Machine vibration can be measured as acceleration, velocity or displacement with selectable frequency ranges between 0.4 Hz and 10 kHz
* Display of true RMS, maximum RMS (MTVV), interval RMS, vibration dose (VDV), total vibration value (aW), peak, maximum peak and crest factor
* Memory for over 1000 measurements with PC interface
* Well suited as vibration dosimeter due to its small dimensions, waterproof design and long battery lifetime

Triaxial vibration meter - VM-BODY

* Component of VibroMetra system
* Measurement of vibration transmitted to the human body by the seat surface, the backrest...

Triaxial vibration meter - VM-BODY

* Component of VibroMetra system
* Measurement of vibration transmitted to the human body by the seat surface, the backrest or the feet to ISO 2631
* For application with a triaxial seat pad accelerometer, e.g. Model KB103SV
* Measuring duration from 1 minute to 1 day
* High reliability by user guidance
* Good / Bad evaluation of the results
* Report function with Excel export
* Offline measurement
* Available as kit:

VM-BODY Kit
Cirrus Research

Noise dosimeter / wireless - doseBadge

The doseBadge is the original wireless personal noise dosemeter and is the ideal instrument for personal noise exposure measurements.

The doseBadge Noise Dosemeter...

Noise dosimeter / wireless - doseBadge

The doseBadge is the original wireless personal noise dosemeter and is the ideal instrument for personal noise exposure measurements.

The doseBadge Noise Dosemeter will measure, store and calculate the parameters essential for compliance Occupational & Industrial Hygiene Noise Regulations. Measurements can be downloaded to the supplied software for analysis & reporting.

Data logging and Time History are provided as standard along with Dual Channel measurement allowing you to measure two sets of data at the same time.

With a rugged, durable metal case, no cables, controls or external microphone, the doseBadge is simple, reliable and easy to use.
{{item.name}}