Power chokes and inductors

select brand


Ruhstrat GmbH

Network choke

The Ruhstrat is part of the Eisenmann Group is manufacturing an AC and DC reactors that are tested and...

Network choke

The Ruhstrat is part of the Eisenmann Group is manufacturing an AC and DC reactors that are tested and certified in accordance with EC directives, European standards and VDE regulations, specifically in DIN EN 61558 and VDE 570, Part 2-20.

The DC reactors is up to 3.000 A and AC reactors for frequencies of 16 2/3 Hz up to 400 Hz for the mains reactor, smoothing reactor, motor reactor,etc.
SCHURTER

Shock choke - 0.45 - 7 A, 600 VDC | DLH

The DLH is a linear choke with THT terminals. Its inductors are positioned vertically...

Shock choke - 0.45 - 7 A, 600 VDC | DLH

The DLH is a linear choke with THT terminals. Its inductors are positioned vertically in their housing. It meets all standards under EN 60938.

The DLH is designed for applications such as RFI suppression choke, chopper amplifiers, switching power supplies, smoothing RFI suppression choke, stepper motor controls and DC drives.

Shock choke - 0.45 - 7 A, 600 VDC | DLF

It is a linear choke with THT-terminals and it also has chopper amplifiers...

Shock choke - 0.45 - 7 A, 600 VDC | DLF

It is a linear choke with THT-terminals and it also has chopper amplifiers and gentle RFI suppression choke. It has DC drives and stepper motor controls with switching power source. It has inductors which are set horizontally in the housing and a appealing SMD version with as EN 60938 standards.

Shock choke - 0.6 - 1 A, 600 VDC | DLNP

The DLNP compact linear choke has an inductor vertically-positioned in the housing and THT terminals....

Shock choke - 0.6 - 1 A, 600 VDC | DLNP

The DLNP compact linear choke has an inductor vertically-positioned in the housing and THT terminals. It is rated up to 600VDC with 2kV eff, winding to ambient isolation voltage.

Applications include DC drives, stepper motor controls, chopper amplifiers, RFi suppression chokes and smoothing and RFI suppression chokes. It meets standards EN 60938 and can be requested as an SMD version.

Shock choke - 0.5 - 16 A, 600 VDC | DS

The Schurter DSF storage choke flat design has THT terminals, the inductor horizontally positioned in...

Shock choke - 0.5 - 16 A, 600 VDC | DS

The Schurter DSF storage choke flat design has THT terminals, the inductor horizontally positioned in the housing, reduced magnetic reversal and constant inductance at a high-alternating field modulation.

Applications include storage of energy in switched power supplies, switch mode, chopper amplifiers and DC drivers that have stepper motor controls. It meets EN 60938 standards.

Shock choke - 0.45 - 4.5 A, 600 VDC | DSF

Description
Storage choke
THT-terminals
Inductor horizontally...

Shock choke - 0.45 - 4.5 A, 600 VDC | DSF

Description
Storage choke
THT-terminals
Inductor horizontally positioned in housing
Constant inductance at high alternating field modulation and large DC magnetization
Reduced magnetic reversal
SMD version on request
Standards
- EN 60938
Alstom Grid

High-voltage line trap - max. 800 kV, 30 - 500 kHz

A line trap can be useful for transmitting data and will work right for managing remote control signals and voice transmissions. This works with a sensible design where many...

High-voltage line trap - max. 800 kV, 30 - 500 kHz

A line trap can be useful for transmitting data and will work right for managing remote control signals and voice transmissions. This works with a sensible design where many lines can be handled at system voltages up to 800 kV in power. This works from 30 to 500 kHZ and can work with a dry type unit that manages a good mounted setup. This can also work in a vertical design. This has a good short-circuit capacity and can manage a self-resonance frequency at more than 500 kHZ. In addition, this unit is a maintenance-free device. It cools itself well and has a lightweight body to make it functional and less likely to require a great deal of maintenance just to make it all work right.
{{item.name}}